journal article Apr 27, 2017

Reproducibility of total ozone column monitoring by the Arosa Brewer spectrophotometer triad

View at Publisher Save 10.1002/2016jd025735
Abstract
AbstractThe historical review of the total ozone column measurements with the Arosa Brewer triad in operation since 1998 is presented. The calibration history of the different instruments and the data quality control performed at Arosa are described. Over the last 15 years, the Brewer triad shows a dispersion of ∼0.4% between the three collocated instruments and a long‐term stability of ±0.5%. These values are a reference metric achievable with well‐maintained Brewer instruments under favorable measurement conditions.
Topics

No keywords indexed for this article. Browse by subject →

References
32
[1]
Absorption Cross Sections of Ozone (ACSO) Status Report(2015) World Meteorological Organization Research Department Atmospheric Research and Environmental Branch GAW Rep. 218. [Available athttp://library.wmo.int/pmb_ged/gaw_218_en.pdf.]
[2]
ATMOZ(2013) European Metrology Research Program (EMRP) ENV59 ATMOZ: Traceability for atmospheric total column ozone. [Available at:http://projects.pmodwrc.ch/atmoz/.]
[3]
Basher R. E.(1982) Review of the Dobson spectrophotometer and its accuracy Project Rep. No. 13 WMO Global Ozone Research and Monit Geneva.
[5]
EUBREWNET(2013) European Cooperation in Science and Technology: COST ES 1207—A European Brewer Network (EUBREWNET). [Available at:http://www.eubrewnet.org/cost1207/.]
[6]
Evans R. D. (2004)
[8]
Large losses of total ozone in Antarctica reveal seasonal ClOx/NOx interaction

J. C. Farman, B. G. Gardiner, J. D. Shanklin

Nature 10.1038/315207a0
[13]
Kerr J. B. (1981)
[14]
Kerr J. B. (1998)
[16]
Komyhr W. D. (1980) Operations Handbook—Ozone Observations With a Dobson Spectrophotometer Global Ozone Res. Monit. Proj. Rep. 6 WMO Geneva Switzerland.
[27]
Staehelin J. J.Kerr R.Evans andK.Vanicek (2003) Comparison of total ozone measurements of Dobson and Brewer spectrophotometers and recommended transfer functions World Meteorological Organization Global Atmosphere Watch (WMO‐GAW) Rep. 149 WMO.
[30]
Multi sensor reanalysis of total ozone

R. J. van der A, M. A. F. Allaart, H. J. Eskes

Atmospheric Chemistry and Physics 10.5194/acp-10-11277-2010
[32]
World Meteorological Organization(2015) Research Department Atmospheric Research and Environment Branch GAW Rep. 224. [Available at:http://library.wmo.int/pmb_ged/gaw_224_en.pdf.]
Metrics
12
Citations
32
References
Details
Published
Apr 27, 2017
Vol/Issue
122(8)
Pages
4735-4745
License
View
Cite This Article
R. Stübi, H. Schill, J. Klausen, et al. (2017). Reproducibility of total ozone column monitoring by the Arosa Brewer spectrophotometer triad. Journal of Geophysical Research: Atmospheres, 122(8), 4735-4745. https://doi.org/10.1002/2016jd025735