journal article Open Access May 18, 2022

Predicting gamma evaluation results of patient‐specific head and neck volumetric‐modulated arc therapy quality assurance based on multileaf collimator patterns and fluence map features: A feasibility study

View at Publisher Save 10.1002/acm2.13622
Abstract
AbstractThe purpose of this study was to develop a predictive model for patient‐specific VMAT QA results using multileaf collimator (MLC) effect and texture analysis. The MLC speed, acceleration and texture analysis features were extracted from 106 VMAT plans as predictors. Gamma passing rate (GPR) was collected as a response class with gamma criteria of 2%/2 mm and 3%/2 mm. The model was trained using two machine learning methods: AdaBoost classification and bagged regression trees model. GPR was classified into the “PASS” and “FAIL” for the classification model using the institutional warning level. The accuracy of the model was assessed using sensitivity and specificity. In addition, the accuracy of the regression model was determined using the difference between predicted and measured GPR. For the AdaBoost classification model, the sensitivity/specificity was 94.12%/100% and 63.63%/53.13% at gamma criteria of 2%/2 mm and 3%/2 mm, respectively. For the bagged regression trees model, the sensitivity/specificity was 94.12%/91.89% and 61.18%/68.75% at gamma criteria of 2%/2 mm and 3%/2 mm, respectively. The root mean square error (RMSE) of difference between predicted and measured GPR was found at 2.44 and 1.22 for gamma criteria of 2%/2 mm and 3%/2 mm, respectively. The promising result was found at tighter gamma criteria 2%/2 mm with 94.12% sensitivity (both bagged regression trees and AdaBoost classification model) and 100% specificity (AdaBoost classification model).
Topics

No keywords indexed for this article. Browse by subject →

References
39
[7]
A technique for the quantitative evaluation of dose distributions

Daniel A. Low, William B. Harms, Sasa Mutic et al.

Medical Physics 10.1118/1.598248
[10]
Commissioning and quality assurance of treatment planning computers

J.Van Dyk, R.B. Barnett, J.E. Cygler et al.

International Journal of Radiation Oncology*Biolog... 10.1016/0360-3016(93)90206-b
[24]
A study on the correlation between plan complexity and gamma index analysis in patient specific quality assurance of volumetric modulated arc therapy

Dhanabalan Rajasekaran, Prakash Jeevanandam, Prabakar Sukumar et al.

Reports of Practical Oncology and Radiotherapy 10.1016/j.rpor.2014.08.006
[34]
Kruse JJ "On the insensitivity of single field planar dosimetry to IMRT inaccuracies" Med Phys
Cited By
17
Metrics
17
Citations
39
References
Details
Published
May 18, 2022
Vol/Issue
23(7)
License
View
Cite This Article
Sangutid Thongsawad, Somyot Srisatit, Todsaporn Fuangrod (2022). Predicting gamma evaluation results of patient‐specific head and neck volumetric‐modulated arc therapy quality assurance based on multileaf collimator patterns and fluence map features: A feasibility study. Journal of Applied Clinical Medical Physics, 23(7). https://doi.org/10.1002/acm2.13622