Technical Note: Evaluation of an iterative reconstruction algorithm for optical CT radiation dosimetry

Medical Physics Vol. 44 No. 12 pp. 6678-6689 · Wiley
Abstract
PurposeIterative CT reconstruction algorithms are gaining popularity as GPU‐based computation becomes more accessible. These algorithms are desirable in x‐ray CT for their ability to achieve similar image quality at a fraction of the dose required for standard filtered backprojection reconstructions. In optical CT dosimetry, the noise reduction capability of such algorithms is similarly desirable because noise has a detrimental effect on the precision of dosimetric analysis, and can create misleading test results. In this study, we evaluate an iterative CT reconstruction algorithm for gel dosimetry, with special attention to the challenging dosimetry of small fields.MethodsAn existing ordered subsets convex algorithm using total variation minimization regularization (OSC‐TV) was implemented. Three datasets, which represent the extreme cases of gel dosimetry, were examined: a large, 15 cm diameter uniform phantom, a 1.35 cm diameter finger phantom, and a 15 cm gel dosimeter irradiated with 3 × 3, 2 × 2, 1 × 1, and 0.6 × 0.6 cm fields. These were scanned on an in‐house scanning laser system, and reconstructed with both filtered backprojection and OSC‐TV with a range of regularization constants. The contrast to artifact + noise ratio (CANR) and penumbra width measurements (80% to 20% and 95% to 5% distances) were used to compare reconstructions.ResultsOur results showed that OSC‐TV can achieve 3–5× improvement in contrast to artifact + noise ratio compared to filtered backprojection, while preserving the shape of steep dose gradients. For very small objects (≤ 0.6 × 0.6 cm fields in a 16 × 16 cm field of view), the mean value in the center of the object can be suppressed if the regularization constant is improperly set, which must be avoided.ConclusionsOverall, the results indicate that OSC‐TV is a suitable reconstruction algorithm for gel dosimetry, provided care is taken in setting the regularization parameter when reconstructing objects that are small compared to the scanner field of view.
Topics

No keywords indexed for this article. Browse by subject →

References
40
[10]
Stray light in cone beam optical computed tomography: II. Reduction using a convergent light source

Kurtis H Dekker, Jerry J Battista, Kevin J Jordan

Physics in Medicine and Biology 10.1088/0031-9155/61/7/2910
[11]
A technique for the quantitative evaluation of dose distributions

Daniel A. Low, William B. Harms, Sasa Mutic et al.

Medical Physics 10.1118/1.598248
[22]
Scanning laser optical computed tomography system for large volume 3D dosimetry

Kurtis H Dekker, Jerry J Battista, Kevin J Jordan

Physics in Medicine and Biology 10.1088/1361-6560/aa5e9c
[32]
Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization

Emil Y Sidky, Xiaochuan Pan

Physics in Medicine and Biology 10.1088/0031-9155/53/17/021
[33]
JørgensenJH JensenTL HansenPC JensenSH SidkyEY PanX.Accelerated gradient methods for total‐variation‐based CT image reconstruction. ArXiv Prepr. ArXiv11054002; 2011.
[35]
Sidky EY "Accurate image reconstruction from few‐views and limited‐angle data in divergent‐beam CT" J X‐Ray Sci Technol (2006)