journal article Sep 28, 2019

Determination of Wair in high‐energy electron beams using graphite detectors

Medical Physics Vol. 46 No. 11 pp. 5195-5208 · Wiley
Abstract
PurposeICRU Report 90 on Key Data for Ionizing‐Radiation Dosimetry: Measurement Standards and Applications (2014) has reaffirmed the recommended value of the mean energy required to create an ion pair in air, Wair, to be 33.97(12) eV. The report also indicates that this “constant” of radiation dosimetry is energy independent above 10 keV, since there is no theoretical or experimental evidence to the contrary. The goal of this investigation is to obtain additional experimental determinations of Wair in high energy beams and thus to verify the suggested energy independence.MethodsWair can be evaluated by combining ionometric and calorimetric measurements with a calculated ratio of the absorbed dose in the ion chamber air cavity and that of the calorimeter absorbing element. In this investigation, a graphite parallel plate chamber and a graphite calorimeter were used and the dose ratio was calculated using the EGSnrc Monte Carlo code. Measurements were made in electron beams from the NRC Vickers linear accelerator at two incident energies, 20 and 35 MeV. A range of average energies at the measurement point were obtained by inserting graphite plates in the primary beam.ResultsThe average value of Wair obtained in this investigation is 33.85(18) eV which is consistent with the recommended value of 33.97(12) eV where the number in brackets represents the combined standard uncertainty of the value, referring to the corresponding last digits. The individual values of Wair do not show any statistically significant energy dependence.ConclusionThe overall combined uncertainty of 0.5% meets the original target of the investigation. A larger‐scale investigation, involving more individual energy points and a wider range of electron energies is required to go further and, for example, comment on the Wair energy dependency question raised by Tessier et al. [Med. Phys. 2018;45:370–381].
Topics

No keywords indexed for this article. Browse by subject →

References
36
[1]
ICRU.Key Data for Ionizing‐Radiation Dosimetry: Measurement Standards and Applications. ICRU Rep 90 (International Comm Radiat Units Meas Bethesda MD);2014.
[6]
IAEA.Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water. Tech Rep TRS‐398. IAEA Vienna;2000.
[12]
ICRU.International Commission on Radiation Units and Measurements. Average Energy Required to Produce an Ion Pair. ICRU Rep 31 (International Comm Radiat Units Meas. Bethesda MD);1979.
[14]
WilliamsAJ BurnsDT McEwenMR.Measurement of the specific heat capacity of the electron‐beam graphite calorimeter. NPL Rep. Rep;1993; NPL.
[16]
SeuntjensJ DuSautoyAR.Review of calorimeter based absorbed dose to water standards. In: Proceedings of International Symposium on Standards and Codes of Practice in Medical Radiation Vienna Nov. 2002. IAEA‐CN‐96‐3;2003;1:37–66.
[20]
SeuntjensJP RossCK KlassenN ShorttKR.A status report on the NRC sealed water calorimeter. Ioniz Radiat Stand Inst Natl Meas Stand. Natl Res Counc Ottawa;1999(March).
[21]
BurnsDT MorrisWT.A graphite calorimeter for electron beam dosimetry. High dose Dosim Radiat Process Proc.1991;IAEA‐SM‐31:123‐136.
[28]
KawrakowI Mainegra‐HingE RogersDWO TessierF WaltersBRB.The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport;2017.https://nrc-cnrc.github.io/EGSnrc/doc/pirs701-egsnrc.pdf
[29]
FippelM.Variance reduction techniques. In: Seco J Verhaegen F eds. Monte Carlo Techniques in Radiation Therapy;2013:29. 10.1201/9781003211846-4
[30]
BergerMJ CourseyJS ZuckerMA ChangJ.ESTAR PSTAR and ASTAR: Computer Programs for Calculating Stopping‐Power and Range Tables for Electrons Protons and Helium Ions (version 1.2.3). National Institute of Standards and Technology Gaithersburg MD;2005.http://physics.nist.gov/Star. Accessed June 12 2017.
[36]
Alexandra BourgouinMM.CIRMS 2017 Conference Gaithersburg MD at NIST March 27–29 2017. In: Vacuum Current: A Possible Systematic Error in Absolute Dose/Kerma Measurements with Ion Chambers. Gaithersburg; 2017:28–29.
Metrics
10
Citations
36
References
Details
Published
Sep 28, 2019
Vol/Issue
46(11)
Pages
5195-5208
License
View
Funding
Natural Sciences and Engineering Research Council of Canada
Cite This Article
Alexandra Bourgouin, Claudiu Cojocaru, Carl Ross, et al. (2019). Determination of Wair in high‐energy electron beams using graphite detectors. Medical Physics, 46(11), 5195-5208. https://doi.org/10.1002/mp.13772