journal article May 21, 2010

Nonlinear inverse reconstruction for real‐time MRI of the human heart using undersampled radial FLASH

Magnetic Resonance in Medicine Vol. 63 No. 6 pp. 1456-1462 · Wiley
View at Publisher Save 10.1002/mrm.22453
Abstract
AbstractA previously proposed nonlinear inverse reconstruction for autocalibrated parallel imaging simultaneously estimates coil sensitivities and image content. This work exploits this property for real‐time MRI, where coil sensitivities need to be dynamically adapted to the conditions generated by moving objects. The development comprises (i) an extension of the nonlinear inverse algorithm to non‐Cartesian k‐space encodings, (ii) its implementation on a graphical processing unit to reduce reconstruction times, and (iii) the use of a convolution‐based iteration, which considerably simplifies the graphical processing unit implementation compared to a gridding technique. The method is validated for real‐time MRI of the human heart at 3 T using radio frequency‐spoiled radial FLASH (pulse repetition time/echo time = 2.0/1.3 ms, flip angle 8°). The results demonstrate artifact‐free reconstructions from only 65–85 spokes, with 256 oversampled data points. Acquisition times of 130–170 ms resulted in 29–38 frames per second for sliding window reconstructions (factor 5). While offline reconstructions required 1–2 sec, real‐time applications with modified parameters and slightly lower image quality were achieved within 90 ms per graphical processing unit. Magn Reson Med 63:1456–1462, 2010. © 2010 Wiley‐Liss, Inc.
Topics

No keywords indexed for this article. Browse by subject →

References
16
[3]
KnollF ClasonC UeckerM StollenbergerS.Improved reconstruction in non‐Cartesian parallel imaging by regularized nonlinear inversion. In Proceedings of the ISMRM 17th Annual Meeting Honolulu 2009; p.2721.
[6]
WajerF PruessmannKP.Major speedup of reconstruction for sensitivity encoding with arbitrary trajectories. In Proceedings of the ISMRM 9th Annual Meeting Glasgow Scotland 2001; p.767.
[7]
EggersH BoernertP BoesigerP.Comparison of gridding‐ and convolution‐based iterative reconstruction algorithms for sensitivity‐encoded non‐cartesian acquisition. In Proceedings of the ISMRM 10th Annual Meeting Honolulu 2002; p.743.
[9]
Bakushinsky AB (2004) 10.1007/978-1-4020-3122-9
[11]
BammerR VigenKK PruessmannKP MarklM MoseleyME.Self‐calibrating radial generalized SENSE. In Proceedings of the ISMRM 12th Annual Meeting Kyoto Japan 2004; p.2414.
Cited By
88
IEEE Transactions on Biomedical Eng...
Magnetic Resonance in Medicine
Metrics
88
Citations
16
References
Details
Published
May 21, 2010
Vol/Issue
63(6)
Pages
1456-1462
License
View
Cite This Article
Martin Uecker, Shuo Zhang, Jens Frahm (2010). Nonlinear inverse reconstruction for real‐time MRI of the human heart using undersampled radial FLASH. Magnetic Resonance in Medicine, 63(6), 1456-1462. https://doi.org/10.1002/mrm.22453
Related

You May Also Like

Sparse MRI: The application of compressed sensing for rapid MR imaging

Michael Lustig, David Donoho · 2007

5,679 citations

Generalized autocalibrating partially parallel acquisitions (GRAPPA)

Mark A. Griswold, Peter M. Jakob · 2002

4,656 citations

SENSE: Sensitivity encoding for fast MRI

Klaas P. Pruessmann, Markus Weiger · 1999

4,133 citations

Movement‐Related effects in fMRI time‐series

Karl J. Friston, Steven Williams · 1996

3,445 citations