journal article Mar 24, 2011

Highly efficient whole‐heart imaging using radial phase encoding‐phase ordering with automatic window selection

Magnetic Resonance in Medicine Vol. 66 No. 4 pp. 1008-1018 · Wiley
View at Publisher Save 10.1002/mrm.22888
Abstract
AbstractThree dimensional (3D) whole‐heart magnetic resonance imaging (MRI) has become an important imaging modality to assess cardiovascular diseases. The main challenges for 3D whole‐heart MRI are long acquisition times, required to achieve high spatial resolution, and image artefacts due to physiological motion. Here we propose to overcome these problems by the combination of an interleaved Radial Phase Encoding trajectory and the Phase Ordering with Automatic Window Selection method. This Radial Phase Encoding‐Phase Ordering with Automatic Window Selection approach yields fast 3D whole‐heart imaging with a high isotropic resolution and high navigator efficiency even for extremely irregular breathing. Numerical simulations were performed and Radial Phase Encoding‐Phase Ordering with Automatic Window Selection was implemented on a clinical scanner. A comparison between the proposed method and a respiratory gated 3D Cartesian approach was carried out. Radial Phase Encoding‐Phase Ordering with Automatic Window Selection leads to a better depiction of coronary arteries and an increase in navigator efficiency. In addition to a high resolution image, this method also provides dynamic respiratory information without an increase in scan time. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.
Topics

No keywords indexed for this article. Browse by subject →

References
29
[4]
SENSE: Sensitivity encoding for fast MRI

Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger et al.

Magnetic Resonance in Medicine 10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s
[6]
Generalized autocalibrating partially parallel acquisitions (GRAPPA)

Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann et al.

Magnetic Resonance in Medicine 10.1002/mrm.10171
[18]
Nuval A "An improved real‐time navigator gating algorithm for reducing motion effects in coronary magnetic resonance angiography" J X‐ray Sci Technol (2003)
[20]
Advances in sensitivity encoding with arbitrary k‐space trajectories

Klaas P. Pruessmann, Markus Weiger, Peter Börnert et al.

Magnetic Resonance in Medicine 10.1002/mrm.1241
[22]
A Computational Approach to Edge Detection

John Canny

IEEE Transactions on Pattern Analysis and Machine... 10.1109/tpami.1986.4767851
Metrics
17
Citations
29
References
Details
Published
Mar 24, 2011
Vol/Issue
66(4)
Pages
1008-1018
License
View
Funding
UK Technology Strategy Board and Engineering and Physical Sciences Research Council Award: TSB/100570
Cite This Article
Christoph Kolbitsch, Claudia Prieto, Jouke Smink, et al. (2011). Highly efficient whole‐heart imaging using radial phase encoding‐phase ordering with automatic window selection. Magnetic Resonance in Medicine, 66(4), 1008-1018. https://doi.org/10.1002/mrm.22888
Related

You May Also Like

Sparse MRI: The application of compressed sensing for rapid MR imaging

Michael Lustig, David Donoho · 2007

5,679 citations

Generalized autocalibrating partially parallel acquisitions (GRAPPA)

Mark A. Griswold, Peter M. Jakob · 2002

4,656 citations

SENSE: Sensitivity encoding for fast MRI

Klaas P. Pruessmann, Markus Weiger · 1999

4,133 citations

Movement‐Related effects in fMRI time‐series

Karl J. Friston, Steven Williams · 1996

3,445 citations