journal article Open Access May 06, 2013

ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA

Magnetic Resonance in Medicine Vol. 71 No. 3 pp. 990-1001 · Wiley
View at Publisher Save 10.1002/mrm.24751
Abstract
PurposeParallel imaging allows the reconstruction of images from undersampled multicoil data. The two main approaches are: SENSE, which explicitly uses coil sensitivities, and GRAPPA, which makes use of learned correlations in k‐space. The purpose of this work is to clarify their relationship and to develop and evaluate an improved algorithm.Theory and MethodsA theoretical analysis shows: (1) The correlations in k‐space are encoded in the null space of a calibration matrix. (2) Both approaches restrict the solution to a subspace spanned by the sensitivities. (3) The sensitivities appear as the main eigenvector of a reconstruction operator computed from the null space. The basic assumptions and the quality of the sensitivity maps are evaluated in experimental examples. The appearance of additional eigenvectors motivates an extended SENSE reconstruction with multiple maps, which is compared to existing methods.ResultsThe existence of a null space and the high quality of the extracted sensitivities are confirmed. The extended reconstruction combines all advantages of SENSE with robustness to certain errors similar to GRAPPA.ConclusionIn this article the gap between both approaches is finally bridged. A new autocalibration technique combines the benefits of both. Magn Reson Med 71:990–1001, 2014. © 2013 Wiley Periodicals, Inc.
Topics

No keywords indexed for this article. Browse by subject →

References
38
[4]
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space

Michael Lustig, John M. Pauly

Magnetic Resonance in Medicine 10.1002/mrm.22428
[12]
Lai P (2010)
[13]
Lustig M (2011)
[18]
Uecker M (2009)
[20]
Griswold M (2002)
[23]
Vasanawala SS (2011)
[30]
She H (2010)
[31]
Sharif B (2011)
[32]
Lustig M (2010)
[33]
Beatty PJ (2006)
[34]
Ding Y (2012)
[36]
Morrison RL (2007)
[37]
Larkman DJ (2005)
[38]
Uecker M (2012)
Cited By
1,221
IEEE Transactions on Neural Network...
Magnetic Resonance in Medicine
Magnetic Resonance in Medicine
Expert Systems with Applications
IEEE Transactions on Computational...
IEEE Transactions on Biomedical Eng...
Expert Systems with Applications
IEEE/ACM Transactions on Computatio...
IEEE Transactions on Medical Imagin...
Nature Methods
Magnetic Resonance in Medicine
Bioengineering
Related

You May Also Like

Sparse MRI: The application of compressed sensing for rapid MR imaging

Michael Lustig, David Donoho · 2007

5,679 citations

Generalized autocalibrating partially parallel acquisitions (GRAPPA)

Mark A. Griswold, Peter M. Jakob · 2002

4,656 citations

SENSE: Sensitivity encoding for fast MRI

Klaas P. Pruessmann, Markus Weiger · 1999

4,133 citations

Movement‐Related effects in fMRI time‐series

Karl J. Friston, Steven Williams · 1996

3,445 citations