journal article Nov 25, 2018

Detection and Identification of the Traces of Explosives with Using of Active Spectral Imaging

View at Publisher Save 10.1002/prep.201800171
Abstract
Abstract
An optical‐electronic laser complex for the standoff detection of traces of explosives was developed with using of the Active Spectral Imaging. The tuning and automatization of the developed complex were performed. Experimental researches in detection of traces of various types of explosives on different substrates were carried out. On average, the probability of detection was 89 % and the probability of identification was 91 %.
Topics

No keywords indexed for this article. Browse by subject →

References
18
[1]
L. A. Skvortsov Laser methods for remote detection of chemical compounds on solid surfaces Technosphera Moscow 2014 p. 208.
[2]
P. M Pellegrino E. L. Holthoff M. E. Farrell Laser-Based Optical Detection of Explosives CRC Press Taylor&Francis Group Boca Raton 2015 p.  405.
[3]
S. Wallin A. Petterson H. Östmark A. Hobro Laser-based standoff detection of explosives: a critical review Anal. Bioanal. Chem.2009 395 259–274. 10.1007/s00216-009-2844-3
[4]
M. Krausa A. Reznev Vapour and Trace Detection of Explosives for Anti-Terrorism Purposes Springer Science+Business Media Dordrecht 2004 p.  152. 10.1007/978-1-4020-2716-1
[5]
A. Petterson I. Johansson S. Wallin M. Nordberg H. Östmark Near real time standoff detection of explosives in a realistic outdoor environment at 55 m distance Propellants Explos. Pyrotech.2009 34 297–306. 10.1002/prep.200800055
[6]
A. Dogariu A. Pidwerbetsky Coherent anti-stokes Raman spectroscopy for detecting explosives in real time Chemical Biological Radiological Nuclear and Explosives Sensing XIII.2012 8358 1–9. 10.1117/12.919568
[7]
G. Bunte M. Heil D. Röseling J. Hürttlen H. Pontius H. Krause Trace Detection of Explosives Vapours by Molecularly Imprinted Polymers for Security Measures Propellants Explos. Pyrotech.2009 34 245–251. 10.1002/prep.200800111
[8]
F. Schnürer M. Rieger A. Eberhardt J. Aniol H. Krause Localisation of IED manufacturing facilities by detection of explosives in sewage water 10th Security Research Conference. Proceedings Berlin Stuttgart: Fraunhofer Verlag.2015 285–291.
[9]
J. M. Nilles T. R. Connell S. T. Stokes H. D. Durst Explosives Detection Using Direct Analysis in Real Time (DART) Mass Spectrometry Propellants Explos. Pyrotech.2010 35 446–451. 10.1002/prep.200900084
[10]
F. Fuchs S. Hugger J. Jarvis Q. K. Yang R. Osterdorf Ch Schilling W. Bronner R. Driad R. Aidam J. Wagner Imaging standoff trace detection of explosives using IR-laser based backscattering Micro- and Nanotachnology Sensors Systems and Application.2016 9836 1–9. 10.1117/12.2223581
[11]
B. E. Bernacki T. A. Blake A. Mendoza T. J. Johnson Visible hyperspectral imaging for standoff detection of explosives on surfaces Optics and Photonics for Counterterrorism and Crime Fighting.2014 7838 1–7. 10.1117/12.870739
[12]
M. E. Morales-Rodriguez L. R. Senesac T. Thundat M. K. Rafailov P. G. Datskos Standoff imaging of chemicals using IR spectroscopy Micro- and Nanotachnology Sensors Systems and Application.2013 8031 1–8. 10.1117/12.885204
[13]
A. A. Pavlenko E. V. Maksimenko L. V. Chernyshova Stand-off detection of HMX traces by active spectral imaging with a tunable CO2laser Quantum Electron.2014 44 383–386. 10.1070/qe2014v044n04abeh015334
[14]
A. A. Pavlenko E. V. Maksimenko L. V. Chernyshova Automated System for Determining of Characteristics of Tunable CO2-laser Datchiki & Systemi (Sensors & Systems).2015 8 33–37.
[15]
E. V. Maksimenko L. V. Chernyshova A. V. Didenko Applying of Methods of Processing of Hyperspectral Data for Identification of Traces of Explosives 17th International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices EDM 2016: Conference Proceedings Novosibirsk State Technical University 2016 358–363. 10.1109/edm.2016.7538758
[16]
J. A. Richards X. Jia Remote Sensing Digital Image Analysis Springer-Verlag Berlin Heidelberg 2006 p. 454. 10.1007/3-540-29711-1
[17]
American National Standards Institute American National Standard for Safe Use of Lasers ANSI Z136.1-2007 (Laser Institute of America) 2007.
[18]
A. A. Pavlenko E. V. Maksimenko L. V. Chernyshova A. V. Didenko Determination of Threshold of Sensitivity of Setup for Stand-off Detection of Traces of Explosives Polzunovsky vestnik.2016 4 68–72.
Related

You May Also Like

Review on Melt Cast Explosives

Pasupala Ravi, Dilip M. Badgujar · 2011

229 citations

Tetrazine Explosives

David E. Chavez, Michael A. Hiskey · 2004

170 citations

Promising CL‐20‐Based Energetic Material by Cocrystallization

Stephen R. Anderson, Pascal Dubé · 2016

92 citations

Review on Energetic Thermoplastic Elastomers (ETPEs) for Military Science

Arun Kanti Sikder, Sreekantha Reddy · 2012

91 citations

Molecular structure of the ideal solid propellant binder

Ross G. Stacer, D. Mark Husband · 1991

83 citations