journal article Jan 01, 1991

EEG versus MEG localization accuracy: Theory and experiment

View at Publisher Save 10.1007/bf01132766
Topics

No keywords indexed for this article. Browse by subject →

References
32
[1]
Ary, J.P., Klien, S.A., and Fender. D.K. Location of sources of scalp evoked potentials: Corrections for skull and scalp thickness. IEEE Trans. Biomed. Engr., 1981, BME-28:447?452. 10.1109/tbme.1981.324817
[2]
Balish, M., Sato, S., Connaughton, P., Kufta, C. Localization of implanted dipoles by magnetoencephalography. Neurology, 1991, 41:1072?1076. 10.1212/wnl.41.7.1072
[3]
Barth D., Beatty J., Broffman J., Sutherling W. Magnetic localization of a dipolar current source implanted in a sphere and a human cranium. Electroenceph. clin. Neurophysiol. 1986, 63:260?273. 10.1016/0013-4694(86)90094-5
[4]
Baule G, and McFee R. Theory of magnetic detection of the heart's electrical activity. J. Appl. Physics, 1965, 36:2066?2073. 10.1063/1.1714404
[5]
Cohen, D., and Cuffin, B.N. Demonstration of useful differences between MEG and EEG. Electroenceph. clin. Neurophysiol. 1983; 56:38?51. 10.1016/0013-4694(83)90005-6
[6]
Cohen, D., Cuffin, B.N., Yunokuchi, K., Maniewski R., Purcell, C., Cosgrove, G.R., Ives, J., Kennedy, J.G., and Schomer, D.L. MEG versus EEG localization test using implanted sources in the human brain. Ann. Neurol., 1990, 28:811?817. 10.1002/ana.410280613
[7]
Cuffin, B.N. A comparison of moving dipole inverse solutions using EEG' and MEG's. IEEE Trans. Biomed. Engr., 1985a, BME 32:905?910. 10.1109/tbme.1985.325622
[8]
Cuffin, B.N. Effects of fissures in the brain on electroencephalograms and magnetoencephalograms. J. Appl. Phys., 1985b, 57:146?153. 10.1063/1.335378
[9]
Cuffin, B.N. Effects of measurement errors and noise on MEG moving dipole inverse solutions. IEEE Trans. Biomed. Engr., 1986 BME-33:854?861. 10.1109/tbme.1986.325779
[10]
Cuffin, B.N. Effects of head shape on EEG's and MEG's. IEEE Trans. Biomed. Engr., 1990, BME-37:44?52. 10.1109/10.43614
[11]
Cuffin, B.N. Eccentric sphere models of the head. IEEE Trans. Biomed. Engr., BME-38, 1991a, in press. 10.1109/10.83607
[12]
Cuffin, B.N. Effects of local variations in skull and scalp thickness on EEG's and MEG's. Submitted to IEEE Trans. Biomed. Engr., 1991b.
[13]
Cuffin, B.N. and Cohen, D. Comparison of the magnetoencephalogram and electroencephalogram. Electroenceph. clin. Neurophysiol., 1979, 47:132?146. 10.1016/0013-4694(79)90215-3
[14]
Darcey, T.M., Ary, J.P., and Fender, D.H. Methods for the localization of electrical sources in the human brain. In: Kornhuber, H.H. and Deeke, L. (Eds.), Progress in Brain Research. Vol. 54, Elsevier, Amsterdam, 1980:128?134. 10.1016/s0079-6123(08)61617-9
[15]
Gaumond, R.P., Lin, J.H., and Geselowitz, D.B. Accuracy of dipole localization with a spherical homogeneous model. IEEE Trans. Biomed. Engr., 1983, BME-30:29?34. 10.1109/tbme.1983.325163
[16]
Hamalainen, M.S. and Sarvas, J. Feasibility of the homogeneous head model in the interpretation of neuromagnetic fields. Phys. Med Biol., 1987, 32:91?97. 10.1088/0031-9155/32/1/014
[17]
Hansen, J.S., Ko, H.W., Fisher, R.S., and Litt,B. Practical limits on the biomagnetic inverse process determined from in vitro measurements in spherical conducting volumes. Phys. Med. Biol., 1988, 33:105?111. 10.1088/0031-9155/33/1/010
[18]
Hari, R., Joutsiniemi, S.L., and Sarvas, J. Spatial resolution of neuromagnetic records: Theoretical calculations in a spherical model. Electroenceph. clin. Neurophysiol., 1988, 71:64?72. 10.1016/0168-5597(88)90020-2
[19]
Hari, R., Lounasmaa O.V. Recording and interpretation of cerebral magnetic fields. Science 1989, 244:432?436. 10.1126/science.2655083
[20]
He, B., Musha, T., Okamoto, Y., Homma, S., Nakajima, Y., and Sato, T. Electric dipole tracing in the brain by means of the boundary element method and its accuracy. IEEE Trans. Biomed. Engr., 1987, BME-34:406?414. 10.1109/tbme.1987.326056
[21]
Henderson, C.J., Butler, S.R., Glass A. The localization of the equivalent dipoles of EEG sources by the application of electric field theory. Electroencephalogr. clin. Neurophysiol., 1975, 39:117?130. 10.1016/0013-4694(75)90002-4
[22]
Janday, B.S. and Swithenby, S.J. Analysis of magnetoencephalographic data using the homogeneous sphere model: empirical tests. Phys. Med. Biol., 1987, 32:105?113. 10.1088/0031-9155/32/1/016
[23]
Kavanagh, R.N., Darcey, T.M., Lehmann, D., and Fender, D.H. Evaluation of methods for three-dimensional localization of electrical sources in the human brain. IEEE Trans. Biomed. Engr., 1978, BME-25:421?429. 10.1109/tbme.1978.326339
[24]
Meijs, J.W.H., ten Voode, B.J., Peters, M.J., Stok, C.J., and Lopes da Silva, F.H. The influence of various head models on EEG's and MEG's. In: Pfurtscheller, G. and Lopes da Silva, F.H. (Eds.), Functional Brain Imaging. Huber, Toronto, 1988:31?46.
[25]
Melcher, J. and Cohen D. Dependence of the MEG on dipole orientation in the rabbit head. Electroenceph clin Neurophysiol. 1988, 70:460?472. 10.1016/0013-4694(88)90024-7
[26]
Okada, Y. Discrimination of localized and distributed current dipole sources and localized single and multiple sources. In: Weinberg, H., Stroink, G., and Katila, T. (Eds.), Biomagnetism: Applications and Theory. Pergamon Press, New York, 1985:266?272.
[27]
Smith D.B., Sidman R.D., Flanigin H, Henke J, and Labiner D. A reliable method for localizing deep intracranial sources of the EEG. Neurology, 1985a, 35:1702?1707. 10.1212/wnl.35.12.1702
[28]
Smith D.B., Sidman R.D., Henke, J.S., et al. Scalp and depth recording of induced deep cerebral potentials. Electroencephalogr. clin. Neurophysiol., 1985b, 55:145?150. 10.1016/0013-4694(83)90180-3
[29]
Stok, C.J. The influence of model parameters on EEG/MEG single dipole source estimation. IEEE Trans. Biomed. Engr., 1987, BME-34:289?296. 10.1109/tbme.1987.326090
[30]
Weinberg H., Brickett P., Coolsma F., and Baff M. Magnetic localization of intracranial dipoles: simulation with a physical model. Electroenceph. clin. Neurophysiol. 1986, 64:159?170. 10.1016/0013-4694(86)90109-4
[31]
Wood, C.C., Cohen, D., Cuffin, B.N., Yarita, M., and Allison, T. Electrical sources in human somatosensory cortex: identification by combined magnetic and potential recordings. Science. 1985, 227:1051?1053. 10.1126/science.3975600
[32]
Yamamoto T., Williamson S.J., Kaufman L., Nicholson C., and Llinas R. Magnetic Localization of neuronal activity in the human brain. Proc. Natl. Acad. Sci. USA, 1988, 85:8732?8736. 10.1073/pnas.85.22.8732
Metrics
62
Citations
32
References
Details
Published
Jan 01, 1991
Vol/Issue
4(2)
Pages
95-103
License
View
Cite This Article
David Cohen, B. Neil Cuffin (1991). EEG versus MEG localization accuracy: Theory and experiment. Brain Topography, 4(2), 95-103. https://doi.org/10.1007/bf01132766