journal article Feb 01, 2019

Magnetic resonance thermometry and its biological applications – Physical principles and practical considerations

View at Publisher Save 10.1016/j.pnmrs.2019.01.003
Topics

No keywords indexed for this article. Browse by subject →

References
249
[1]
Thermal ablation of tumours: biological mechanisms and advances in therapy

Katrina F. Chu, Damian E. Dupuy

Nature Reviews Cancer 2014 10.1038/nrc3672
[2]
Panych "The physics of MRI safety" J. Magn. Reson. Imaging (2018) 10.1002/jmri.25761
[3]
Shellock "Radiofrequency energy-induced heating during MR procedures: a review" J. Magn. Reson. Imaging (2000) 10.1002/1522-2586(200007)12:1<30::aid-jmri4>3.0.co;2-s
[4]
Hall-craggs "Thermal therapies in the body monitored by MRI" Encycl. Magn. Reson. (2007)
[5]
Hamilton "Therapy monitoring by MRI" Encycl. Magn. Reson. (2007)
[6]
Norris "Safety considerations in MRI" EMagRes (2007)
[7]
Schenck "Safety and sensory aspects of main and gradient fields in MRI" EMagRes (2013)
[8]
Ahmed "Magnetic resonance imaging safety: implications for cardiovascular patients" J. Cardiovasc. Magn. Reson. (2001) 10.1081/jcmr-100107466
[9]
Shellock "Biologic effects, safety, and patient care" Radiology (2004) 10.1148/radiol.2323030830
[10]
Shellock "Bioeffects and safety of radiofrequency electromagnetic fields" EMagRes (2007) 10.1002/9780470034590.emrstm0025
[11]
Parker "Temperature distribution measurements in two-dimensional NMR imaging" Med. Phys. (1983) 10.1118/1.595307
[12]
Parker "Applications of NMR imaging in hyperthermia: an evaluation of the potential for localized tissue heating and noninvasive temperature monitoring" IEEE Trans. Biomed. Eng. (1984) 10.1109/tbme.1984.325382
[13]
Schneider "Proton magnetic resonance chemical shift of free (gaseous) and associated (liquid) hydride molecules" J. Chem. Phys. (1958) 10.1063/1.1744199
[14]
Muller "Concerning structural models for water and chemical-shift data" J. Chem. Phys. (1965) 10.1063/1.1697163
[15]
Hindman "Proton resonance shift of water in the gas and liquid states" J. Chem. Phys. (1966) 10.1063/1.1726676
[16]
Lutz "A 1H-NMR method for determining temperature in cell culture perfusion systems" Magn. Reson. Med. (1993) 10.1002/mrm.1910290120
[17]
Kuroda "Non-invasive temperature measurement by means of NMR parameters-Use of proton chemical shift with spectral estimation technique" Med. Biol. Eng. Comput. (1991)
[18]
Y. Ishihara, A. Calderon, H. Waranabee, K. Mori, K. Okamoto, Y. Suzuki, K. Sato, K. Kuroda, N. Nakagawa, S. Tsuysumi, A precise and fast temperature mapping method using water proton chemical shift, in: SMRM, 1992, p. 4803.
[19]
Ishihara "A precise and fast temperature mapping using water proton chemical shift" Magn. Reson. Med. (1995) 10.1002/mrm.1910340606
[20]
De Poorter "The proton-resonance-frequency-shift method compared with molecular diffusion for quantitative measurement of two-dimensional time-dependent temperature distribution in a phantom" J. Magn. Reson. Ser. B. (1994) 10.1006/jmrb.1994.1035
[21]
De Poorter "Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle" Magn. Reson. Med. (1995) 10.1002/mrm.1910330111
[22]
Hall "Hall, mapping of pH and temperature distribution using chemical-shift-resolved tomography" J. Magn. Reson. (1985)
[23]
De Poorter "Noninvasive MRI thermometry with the proton resonance frequency method Study of susceptibility effects" Magn. Reson. Med. (1995) 10.1002/mrm.1910340313
[24]
Muller "Temperature dependence of chemical shifts of protons in hydrogen bonds" J. Chem. Phys. (1965) 10.1063/1.1696408
[25]
Peters "Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry" Magn. Reson. Med. (1998) 10.1002/mrm.1910400316
[26]
McDannold "Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: review of validation studies" Int. J. Hyperth. (2005) 10.1080/02656730500096073
[27]
Peters "Proton-resonance frequency shift MR thermometry is affected by changes in the electrical conductivity of tissue" Magn. Reson. Med. (2000) 10.1002/(sici)1522-2594(200001)43:1<62::aid-mrm8>3.0.co;2-1
[28]
MacFall "1H MRI phase thermometry in vivo in canine brain, muscle, and tumor tissue" Med. Phys. (1996) 10.1118/1.597760
[29]
Sinha "Phase imaging on a.2-T MR scanner: application to temperature monitoring during ablation procedures" J. Magn. Reson. Imaging. (1997) 10.1002/jmri.1880070522
[30]
Peters "Magnetic resonance thermometry for predicting thermal damage: an application of interstitial laser coagulation in an in vivo canine prostate model" Magn. Reson. Med. (2000) 10.1002/1522-2594(200012)44:6<873::aid-mrm8>3.0.co;2-x
[31]
Kuroda "Optimization of chemical shift selective suppression of fat" Magn. Reson. Med. (1998) 10.1002/mrm.1910400402
[32]
Quesson "Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney" NMR Biomed. (2011) 10.1002/nbm.1563
[33]
Ramsay "MR thermometry in the human prostate gland at 3.0T for transurethral ultrasound therapy" J. Magn. Reson. Imaging (2013) 10.1002/jmri.24063
[34]
Rieke "Comparison of temperature processing methods for monitoring focused ultrasound ablation in the brain" J. Magn. Reson. Imaging (2013) 10.1002/jmri.24117
[35]
Marx "Specialized volumetric thermometry for improved guidance of MRgFUS in brain" Magn. Reson. Med. 78 (2017) 10.1002/mrm.26385
[36]
Svedin "Multiecho pseudo-golden angle stack of stars thermometry with high spatial and temporal resolution using k-space weighted image contrast" Magn. Reson. Med. (2018) 10.1002/mrm.26797
[37]
Chung "Optimization of spoiled gradient-echo phase imaging forin vivo localization of a focused ultrasound beam" Magn. Reson. Med. (1996) 10.1002/mrm.1910360513
[38]
Vogel "Use of fast spin echo for phase shift magnetic resonance thermometry" J. Magn. Reson. Imaging. (2003) 10.1002/jmri.10393
[39]
Streicher "Fast accurate MR thermometry using phase referenced asymmetric spin-echo EPI at high field" Magn. Reson. Med. (2014) 10.1002/mrm.24681
[40]
Hargreaves "Rapid gradient-echo imaging" J. Magn. Reson. Imaging (2012) 10.1002/jmri.23742
[41]
Holbrook "Real-time MR thermometry for monitoring HIFU ablations of the liver" Magn. Reson. Med. (2010) 10.1002/mrm.22206
[42]
Kickhefel "Accuracy of real-time MR temperature mapping in the brain: a comparison of fast sequences" Phys. Medica (2010) 10.1016/j.ejmp.2009.11.006
[43]
Cernicanu "Validation of fast MR thermometry at 1.5 T with gradient-echo echo planar imaging sequences: phantom and clinical feasibility studies" NMR Biomed. (2008) 10.1002/nbm.1267
[44]
Weidensteiner "Real-time MR temperature mapping of rabbit liver in vivo during thermal ablation" Magn. Reson. Med. (2003) 10.1002/mrm.10521
[45]
de Zwart "Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation" Magn. Reson. Med. (1999) 10.1002/(sici)1522-2594(199907)42:1<53::aid-mrm9>3.0.co;2-s
[46]
Madore "Multipathway sequences for MR thermometry" Magn. Reson. Med. (2011) 10.1002/mrm.22844
[47]
Todd "Temporally constrained reconstruction applied to MRI temperature data" Magn. Reson. Med. (2009) 10.1002/mrm.22012
[48]
Denis de Senneville "Extended Kalman filtering for continuous volumetric MR-temperature imaging" IEEE Trans. Med. Imaging (2013) 10.1109/tmi.2012.2234760
[49]
Roujol "Real-time MR-thermometry and dosimetry for interventional guidance on abdominal organs" Magn. Reson. Med. (2010) 10.1002/mrm.22309
[50]
Jonathan "Volumetric MRI thermometry using a three-dimensional stack-of-stars echo-planar imaging pulse sequence" Magn. Reson. Med. (2018) 10.1002/mrm.26862

Showing 50 of 249 references

Metrics
165
Citations
249
References
Details
Published
Feb 01, 2019
Vol/Issue
110
Pages
34-61
License
View
Funding
NIH Award: R01EB013433
Siemens Healthcare
Mark H. Huntsman
Cite This Article
Henrik Odéen, Dennis L. Parker (2019). Magnetic resonance thermometry and its biological applications – Physical principles and practical considerations. Progress in Nuclear Magnetic Resonance Spectroscopy, 110, 34-61. https://doi.org/10.1016/j.pnmrs.2019.01.003