journal article Sep 01, 2013

Effect of long-term operation on the performance of polypropylene and polyvinylidene fluoride membrane contactors for CO2 absorption

View at Publisher Save 10.1016/j.seppur.2013.05.051
Topics

No keywords indexed for this article. Browse by subject →

References
25
[1]
Kunze "Assessment of oxy-fuel, pre- and post-combustion-based carbon capture for future IGCC plants" Appl. Energy (2012) 10.1016/j.apenergy.2012.01.013
[2]
Kuramochi "Comparative assessment of CO2 capture technologies for carbon-intensive industrial processes" Prog. Energy Combust. (2012) 10.1016/j.pecs.2011.05.001
[3]
Luis "Recent developments in membrane-based technologies for CO2 capture" Prog. Energy Combust. (2012) 10.1016/j.pecs.2012.01.004
[4]
Favre "Membrane processes and postcombustion carbon dioxide capture: challenges and prospects" Chem. Eng. J. (2011) 10.1016/j.cej.2011.01.010
[5]
Review of CO2 absorption using chemical solvents in hollow fiber membrane contactors

Jing-Liang Li, Bing-Hung Chen

Separation and Purification Technology 2005 10.1016/j.seppur.2004.09.008
[6]
Favre "Membrane contactors for intensified post-combustion carbon dioxide capture by gas–liquid absorption processes" J. Membr. Sci. (2012) 10.1016/j.memsci.2012.03.019
[7]
Khaisri "Comparing membrane resistance absorption performance of three different membranes in a gas absorption membrane contactor" Sep. Purif. Technol. (2009) 10.1016/j.seppur.2008.10.035
[8]
Dindore "Membrane-solvent selection for CO2 removal using membrane gas–liquid contactors" Sep. Purif. Technol. (2004) 10.1016/j.seppur.2004.01.014
[9]
Chen "Chemical absorption of carbon dioxide with asymmetrically heated polytetrafluoroethylene membranes" J. Environ. Manage. (2011) 10.1016/j.jenvman.2010.08.014
[10]
Porcheron "Hollow fiber membrane contactors for CO2 capture: from lab-scale screening to pilot-plant module conception" Energy Proc. (2011) 10.1016/j.egypro.2011.01.117
[11]
Mansourizadeh "Experimental study of CO2 absorption/stripping via PVDF hollow fiber membrane contactor" Chem. Eng. Res. Des. (2012) 10.1016/j.cherd.2011.08.017
[12]
deMotigny "Using polypropylene and polytetrafluoroethylene membranes in a membrane contactor for CO2 absorption" J. Membr. Sci. (2006) 10.1016/j.memsci.2005.10.024
[13]
Atchariyawut "Separation of CO2 from CH4 by using gas–liquid membrane contacting process" J. Membr. Sci. (2007) 10.1016/j.memsci.2007.07.030
[14]
Mansourizadeh "A developed asymmetric PVDF hollow fiber membrane structure for CO2 absorption" Int. J. Greenhouse Gas Control (2011) 10.1016/j.ijggc.2010.09.007
[15]
Rongwong "Experimental study on membrane wetting in gas–liquid membrane contacting process for CO2 absorption by single and mixed absorbents" Sep. Purif. Technol. (2009) 10.1016/j.seppur.2009.07.009
[16]
Wang "Impact of DEA solutions with and without CO2 loading on porous polypropylene membranes intended for use as contactors" J. Membr. Sci. (2004) 10.1016/j.memsci.2003.10.022
[17]
Boributh "A modeling study on the effects of membrane characteristics and operating parameters on physical absorption of CO2 by hollow fiber membrane contactor" J. Membr. Sci. (2011) 10.1016/j.memsci.2011.06.029
[18]
Kumar "New absorption liquids for the removal of CO2 from dilute gas streams using membrane contactors" Chem. Eng. Sci. (2002) 10.1016/s0009-2509(02)00041-6
[19]
Influence of membrane wetting on CO2 capture in microporous hollow fiber membrane contactors

R. Wang, H.Y. Zhang, P.H.M. Feron et al.

Separation and Purification Technology 2005 10.1016/j.seppur.2005.04.007
[20]
Ismail "A comparative study on the structure and performance of porous polyvinylidene fluoride and polysulfone hollow fiber membranes for CO2 absorption" J. Membr. Sci. (2010) 10.1016/j.memsci.2010.09.021
[21]
Tasselli "Morphology and transport property control of modified poly (ether ether ketone) (PEEKWC) hollow fiber membranes prepared from PEEKWC/PVP blends: influence of the relative humidity in the air gap" J. Membr. Sci. (2005) 10.1016/j.memsci.2005.01.014
[22]
Xu "Poly (vinyl chloride) (PVP) hollow fiber ultrafiltration membranes prepared from PVC/additives/solvent" J. Membr. Sci. (2002) 10.1016/s0376-7388(02)00261-2
[23]
Mansourizadeh "Effect of operating conditions on the physical and chemical CO2 absorption through the PVDF hollow fiber membrane contactor" J. Membr. Sci. (2010) 10.1016/j.memsci.2010.02.054
[24]
Lu "Wetting mechanism in mass transfer process of hydrophobic membrane gas absorption" J. Membr. Sci. (2008) 10.1016/j.memsci.2007.09.051
[25]
Gabelman "Hollow fiber membrane contactors" J. Membr. Sci. (1999) 10.1016/s0376-7388(99)00040-x
Cited By
51
Metrics
51
Citations
25
References
Details
Published
Sep 01, 2013
Vol/Issue
116
Pages
300-306
Cite This Article
Zhaohui Zhang, Bin Zhao, Hongwei Zhang, et al. (2013). Effect of long-term operation on the performance of polypropylene and polyvinylidene fluoride membrane contactors for CO2 absorption. Separation and Purification Technology, 116, 300-306. https://doi.org/10.1016/j.seppur.2013.05.051