journal article Oct 01, 2015

A novel electromagnetic navigation tool for acetabular surgery

Injury Vol. 46 pp. S71-S74 · Elsevier BV
View at Publisher Save 10.1016/s0020-1383(15)30021-8
Topics

No keywords indexed for this article. Browse by subject →

References
22
[1]
Bishop "Osseous fixation pathways in pelvic and acetabular fracture surgery: osteology, radiology, and clinical applications" J Trauma Acute Care Surg (2012) 10.1097/ta.0b013e318246efe5
[2]
Sullivan "Geriatric fractures about the hip: divergent patterns in the proximal femur, acetabulum, and pelvis" Orthopedics (2014) 10.3928/01477447-20140225-50
[3]
Gras "Screw-versus plate-fixation strength of acetabular anterior column fractures: a biomechanical study" J Trauma Acute Care Surg (2012) 10.1097/ta.0b013e3182463b45
[4]
Letournel (1993)
[5]
Ochs "Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional technique" Injury (2010) 10.1016/j.injury.2010.07.502
[6]
Mouhsine "Percutaneous retrograde screwing for stabilisation of acetabular fractures" Injury (2005) 10.1016/j.injury.2004.09.016
[7]
Ruan "Percutaneous screw fixation for the acetabular fracture with quadrilateral plate involved by three-dimensional fluoroscopy navigation: surgical technique" Injury (2012) 10.1016/j.injury.2011.08.002
[8]
Gras "Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study" J Orthop Trauma (2012) 10.1097/bot.0b013e318234d443
[9]
Cole "Acetabular fracture fixation via a modified Stoppa limited intrapelvic approach. Description of operative technique and preliminary treatment results" Clin Orthop Relat Res (1994)
[10]
Lehmann "[The stoppa approach for treatment of acetabular fractures]" Z Orthop Unfall (2014)
[11]
Culemann "Infra-acetabular corridor–technical tip for an additional screw placement to increase the fixation strength of acetabular fractures" J Trauma (2011) 10.1097/ta.0b013e3181f45f91
[12]
Ji "Digital anatomical measurements of safe screw placement at superior border of the arcuate line for acetabular fractures" BMC Musculoskelet Disord (2015) 10.1186/s12891-015-0518-1
[13]
Marintschev "Biomechanical comparison of different acetabular plate systems and constructs–the role of an infra-acetabular screw placement and use of locking plates" Injury (2012) 10.1016/j.injury.2011.11.009
[14]
Ochs "Changes in the treatment of acetabular fractures over 15 years: Analysis of 1266 cases treated by the German Pelvic Multicentre Study Group (DAO/DGU)" Injury (2010) 10.1016/j.injury.2010.04.010
[15]
Chen "Fluoroscopic views for safe insertion of lag screws into the posterior column of the acetabulum" BMC Musculoskelet Disord (2014) 10.1186/1471-2474-15-303
[16]
Wong "Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation" Injury (2015) 10.1016/j.injury.2015.01.038
[17]
Oberst "Effects of three-dimensional navigation on intraoperative management and early postoperative outcome after open reduction and internal fixation of displaced acetabular fractures" J Trauma Acute Care Surg (2012) 10.1097/ta.0b013e318254308f
[18]
Hoffmann "A novel computer navigation system for retrograde drilling of osteochondral lesions" Sports Med Arthrosc (2014) 10.1097/jsa.0000000000000036
[19]
Hoffmann "Accuracy analysis of a novel electromagnetic navigation procedure versus a standard minimally invasive method for arthroscopically assisted acromioclavicular joint reconstructions" Arthroscopy (2014) 10.1016/j.arthro.2014.03.011
[20]
Hopf "Percutaneous iliosacral screw fixation after osteoporotic posterior ring fractures of the pelvis reduces pain significantly in elderly patients" Injury (2015) 10.1016/j.injury.2015.04.036
[21]
Wong "Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation" Injury (2015) 10.1016/j.injury.2015.01.038
[22]
Giráldez-Sánchez "Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis" Injury (2015) 10.1016/j.injury.2014.10.058
Metrics
13
Citations
22
References
Details
Published
Oct 01, 2015
Vol/Issue
46
Pages
S71-S74
License
View
Cite This Article
Wolfgang Lehmann, Johannes M. Rueger, Jakob Nuechtern, et al. (2015). A novel electromagnetic navigation tool for acetabular surgery. Injury, 46, S71-S74. https://doi.org/10.1016/s0020-1383(15)30021-8
Related

You May Also Like

Bone substitutes: An update

Peter V. Giannoudis, Haralambos Dinopoulos · 2005

1,610 citations

Epidemiology and social costs of hip fracture

Nicola Veronese, Stefania Maggi · 2018

798 citations