journal article Dec 01, 2003

Blue Phosphors of Dinuclear and Mononuclear Copper(I) and Silver(I) Complexes of 3,5-Bis(trifluoromethyl)pyrazolate and the Related Bis(pyrazolyl)borate

View at Publisher Save 10.1021/ic0347586
Topics

No keywords indexed for this article. Browse by subject →

References
30
[1]
La Monica G. Prog. Inorg. Chem. (1997)
[2]
Strong Closed-Shell Interactions in Inorganic Chemistry

Pekka Pyykkö

Chemical Reviews 1997 10.1021/cr940396v
[3]
Yam V. W.-W. Chem. Soc. Rev. (1999) 10.1039/a804249g
[4]
Yang G. Inorg. Chem. (2003) 10.1021/ic026051+
[5]
Dias H. V. R. J. Organometallics (2002) 10.1021/om010886v
[6]
Bovio B. Inorg. Chim. Acta (1984) 10.1016/s0020-1693(00)83616-6
[7]
Banditelli G. Gazz. Chim. Ital. (1982)
[8]
Dias H. V. R. J. Fluor. Chem. (2000) 10.1016/s0022-1139(99)00313-9
[9]
Ehlert M. K. Can. J. Chem. (1997) 10.1139/v97-057
[10]
We (1999)
[11]
Dias H. V. R. J. Am. Chem. Soc. (2003) 10.1021/ja036736o
[12]
Omary M. A. Inorg. Chem. (2003) 10.1021/ic034066h
[13]
Haneline M. R. J. Am. Chem. Soc. (2002) 10.1021/ja0166794
[14]
Examples J. Appl. Phys. (2000) 10.1063/1.373496
[15]
Dias H. V. R. Inorg. Chem. (1995) 10.1021/ic00125a044
[16]
Dias H. V. R. J. Am. Chem. Soc. (1995) 10.1021/ja00150a053
[17]
Dias H. V. R. Inorg. Chem. (1996) 10.1021/ic960186w
[18]
Trofimenko, S.Scorpionates:  The Coordination Chemistry ofPolypyrazolylborate Ligands; Imperial College:  London, 1999. 10.1142/p148
[19]
Steady-state photoluminescence spectra were acquired with a PTI QuantaMaster model QM-4 scanning spectrofluorometer equipped with a 75-W xenon lamp, emission and excitation monochromators, excitation correction unit, and a PMT detector. The spectra were corrected for the detector wavelength-dependent response. Lifetime data utilized a nitrogen laser interfaced with a tunable dye laser and a frequency doubler, as part of fluorescence and phosphorescence subsystem add-ons to the PTI instrument. The 337.1 nm line of the N2laser was used to pump a freshly-prepared 1 × 10-3M solution of the organic continuum laser dye Coumarin-540A in ethanol, the output of which was tuned and frequency doubled to attain the 265 nm excitation used to generate the time-resolved data.
[20]
Alkorta I. New J. Chem (1999) 10.1039/a904292j
[21]
Wootton J. L. Inorg. Chem. (1997) 10.1021/ic961006l
[22]
Swaminathan M. Spectrochim. Acta (1983) 10.1016/0584-8539(83)80087-7
[23]
Catalan J. J. Am. Chem. Soc. (1992) 10.1021/ja00039a014
[24]
Sorrell T. N. Inorg. Chem. (1987) 10.1021/ic00259a029
[25]
Turro N. J. (1978)
[26]
McGlynn S. P. (1969)
[27]
Chao H.-Y. J. Am. Chem. Soc. (2002) 10.1021/ja0209417
[28]
McCleskey T. M. Inorg. Chem. (1992) 10.1021/ic00036a002
[29]
Forward J. J. Am. Chem. Soc. (1995) 10.1021/ja00140a042
[30]