Optimization of Treatment Geometry to Reduce Normal Brain Dose in Radiosurgery of Multiple Brain Metastases with Single–Isocenter Volumetric Modulated Arc Therapy

View at Publisher Save 10.1038/srep34511
Abstract
AbstractTreatment of patients with multiple brain metastases using a single-isocenter volumetric modulated arc therapy (VMAT) has been shown to decrease treatment time with the tradeoff of larger low dose to the normal brain tissue. We have developed an efficient Projection Summing Optimization Algorithm to optimize the treatment geometry in order to reduce dose to normal brain tissue for radiosurgery of multiple metastases with single-isocenter VMAT. The algorithm: (a) measures coordinates of outer boundary points of each lesion to be treated using the Eclipse Scripting Application Programming Interface, (b) determines the rotations of couch, collimator and gantry using three matrices about the cardinal axes, (c) projects the outer boundary points of the lesion on to Beam Eye View projection plane, (d) optimizes couch and collimator angles by selecting the least total unblocked area for each specific treatment arc and (e) generates a treatment plan with the optimized angles. The results showed significant reduction in the mean dose and low dose volume to normal brain, while maintaining the similar treatment plan qualities on the thirteen patients treated previously. The algorithm has the flexibility with regard to the beam arrangements and can be integrated in the treatment planning system for clinical application directly.
Topics

No keywords indexed for this article. Browse by subject →

References
25
[1]
Thomas, E. M. et al. Comparison of plan quality and delivery time between volumetric arc therapy (RapidArc) and Gamma knife radiosurgery for multiple cranial metastases. Neurosurgery 75, 409–418 (2014) 10.1227/neu.0000000000000448
[2]
Chin, L. S., Ma, L. & DiBiase, S. Radiation following gamma knife surgery: a case-controlled comparison of treatment parameters and long-term clinical follow up. J Neurosurgery 94, 899–904 (2001). 10.3171/jns.2001.94.6.0899
[3]
Otto, K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med. Phys. 35, 310–317 (2008). 10.1118/1.2818738
[4]
Clark, G. M., Popple, R. A., Young, P. E. & Fiveash, J. B. Feasibility of single-isocenter VMAT radiosurgery for treatment of multiple brain metastases. Int. J. Radiat Oncol Biol Phys 76, 296–302 (2010). 10.1016/j.ijrobp.2009.05.029
[5]
Wolff, H. A., Wagner, D. M., Christiansen, H., Hess, C. F. & Vormerk, H. Single fraction radiosurgery using Rapid Arc for treatment of intracranial targets. Radiat Oncol 5, 77–84 (2010). 10.1186/1748-717x-5-77
[6]
Clark, G. M. et al. Plan quality and treatment planning technique for single isocenter cranial radiosurgery with VMAT. Pract Radiat Oncol 2, 306–313 (2012). 10.1016/j.prro.2011.12.003
[7]
Wang, J. Z., et al. Intensity-modulated radiosurgery with rapidarc for multiple brain metastases and comparison with static approach. Med Dosim 37, 31–36 (2012). 10.1016/j.meddos.2010.12.010
[8]
Huang, C., Ren, L., Kirkpatrick, J. & Wang, Z. Treatment of multiple brain metastases using SRS single isocenter VMAT: comparison with conventional conformal arc and static beam SRS. Med. Phys. 39, 3854 (2012). 10.1118/1.4735734
[9]
Huang, Y. et al. Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA). Radiat Oncol 112, 128–132 (2014). 10.1016/j.radonc.2014.05.009
[10]
Smith, K., Ford, E., Wong, J. & McNutt, T. Volumetric arc treatment of multiple brain metastases. Med. Phys. 36, 2646 (2009). 10.1118/1.3182028
[11]
Voges, J. et al. Risk analysis of linear accelerator radiosurgery. Int. J. Radiation Oncology Biol. Phys. 36, 1055–1063 (1996). 10.1016/s0360-3016(96)00422-1
[12]
Blonigen, B. J. et al. Irradiated volume as a predictor of brain radionecrosis after linear accelerator stereotactic radiosurgery. Int. J. Radiation Oncology Biol. Phys. 77, 996–1001 (2010). 10.1016/j.ijrobp.2009.06.006
[13]
Korytko, T. et al. 12G Gamma knife radiosurgical volume is a predictor for radiation necrosis in non-avm intracranial tumors. Int. J. Radiation Oncology Biol. Phys. 64, 419–424 (2006). 10.1016/j.ijrobp.2005.07.980
[14]
Minniti, et al. Stereotactic radiosurgery for brain metastases: analysis of outcome and risk of brain radionecrosis. Radiation Oncology 6, 48–56 (2011).
[15]
Kang, J., Ford, E. C., Smith, K. & Wong, J. McNutt TR. A method of optimizing LINAC treatment geometry for VMAT of multiple brain metastases. Med. Phys. 37, 4146–4154 (2010). 10.1118/1.3455286
[16]
Audet, C. et al. Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs. Med. Phys. 38, 5863–5872 (2011). 10.1118/1.3641874
[17]
Wen, N. et al. Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system. Med Phys. 43, 2527 (2016) 10.1118/1.4947199
[18]
Prendergast, B. M. et al. Improved clinical efficiency in CNS stereotactic radiosurgery using a flattening filter free linear accelerator. J Radiosurg SBRT. 1, 117–122 (2011)
[19]
Ma, L. et al. Apparatus dependence of normal brain tissue dose in stereotactic radiosurgery for multiple brain metastases. J Neurosurg. 114, 1580–1584 (2011) 10.3171/2011.1.jns101056
[20]
McDonald, D. et al. Compared radiation dose spillage from the Gamma Knife Perfexion with that from volumetric modulated arc radiosurgery during treatment of multiple brain metastases in a single fraction. J Neurosury (Suppl 2) 121, 51–59 (2014) 10.3171/2014.7.gks141358
[21]
Jairam, V., Chiang, L. S. V., Yu, B. J. & Knisely, J. P. Role of stereotactic radiosurgery in patients with more than four metastases. CNS Oncol. 2, 1–18 (2013) 10.2217/cns.12.38
[22]
Karlsson, B., Lax. I. & Söderman, M. Clinical outcome of radiosurgery for cerebral arteriovenous malformations; Factors influencing the risk for complications following Gamma Knife radiosurgery of cerebral arteriovenous malformations. Radiother Oncol. 43, 275–280 (1997) 10.1016/s0167-8140(97)00060-1
[23]
Flickinger, J. C., Kondziolka, D., Pollock, B. E., Maitz, A. H. & Lunsford, L. D. Complications from arteriovenous malformation radiosurgery: multivariate analysis and risk modeling. Int J Radiat Oncol Biol Phys. 38, 485–490 (1997) 10.1016/s0360-3016(97)89481-3
[24]
Voges, J. et al. Risk analysis of LINAC radiosurgery in patients with arteriovenous malformations (AVM). Acta Neurochir Suppl. 68, 118–123 (1997)
[25]
Nakamura, J. L. et al. Dose conformity of gamma knife radiosurgery and risk factors for complications. Int J Radiat Oncol Biol Phys. 51, 1313–1319 (2001) 10.1016/s0360-3016(01)01757-6
Metrics
41
Citations
25
References
Details
Published
Sep 30, 2016
Vol/Issue
6(1)
License
View
Cite This Article
Qixue Wu, Karen Chin Snyder, Chang Liu, et al. (2016). Optimization of Treatment Geometry to Reduce Normal Brain Dose in Radiosurgery of Multiple Brain Metastases with Single–Isocenter Volumetric Modulated Arc Therapy. Scientific Reports, 6(1). https://doi.org/10.1038/srep34511