journal article Open Access Jan 04, 2023

Estimation of Reference Intervals from Routine Data Using the refineR Algorithm—A Practical Guide

View at Publisher Save 10.1093/jalm/jfac101
Abstract
AbstractBackgroundAccurate reference intervals are essential for the interpretation of laboratory test results. Typically, they are determined by the central 95% range of test results from a predefined reference population. As these direct studies can face practical and ethical challenges, indirect methods using routine measurements offer an alternative approach.MethodsWe provide step-by-step guidance on how to apply an indirect method in practice using refineR, the most recently published indirect method, and showcase the application by evaluating real-world data of 12 prespecified analytes. Measurements were retrieved from ARUP Laboratories’ data warehouse, and were obtained from routine patient testing on cobas c502 or e602 analyzers. Test results were prefiltered and cleaned and, if necessary, physiologically partitioned prior to estimating reference intervals using refineR. Estimated reference intervals were then compared to established intervals provided by the manufacturer.ResultsFor most analytes, the reference intervals estimated by refineR were comparable to those provided by the manufacturer, shown by overlapping confidence intervals at both reference limits, or only the upper or lower limit. For thyroid-stimulating hormone, refineR estimated higher reference limits, while estimates for prealbumin were lower compared to the established reference interval.ConclusionsWe applied the refineR algorithm to a variety of real-world data sets resulting in reference intervals similar to intervals previously established by direct methods. We further provide practical guidance and a code example on how to apply an indirect method in a real-world scenario facilitating their access and thus their use in laboratory settings.
Topics

No keywords indexed for this article. Browse by subject →

References
21
[1]
Horn "Reference intervals: an update" Clin Chim Acta (2003) 10.1016/s0009-8981(03)00133-5
[2]
Jones "Reference intervals" Clin Biochem Rev (2008)
[3]
Clinical and Laboratory Standards Institute (2010)
[4]
Jones "Indirect methods for reference interval determination—review and recommendations" Clin Chem Lab Med (2018) 10.1515/cclm-2018-0073
[5]
Zierk "Data mining of pediatric reference intervals" J Lab Med (2021) 10.1515/labmed-2021-0120
[6]
Ozarda "Reference intervals: current status, recent developments and future considerations" Biochem Med (2016) 10.11613/bm.2016.001
[7]
Özcürümez "Determination and verification of reference interval limits in clinical chemistry. Recommendations for laboratories on behalf of the working group guide limits of the DGKL with respect to ISO Standard 15189 and the guideline of the German Medical Association" J Lab Med (2019) 10.1515/labmed-2018-0500
[8]
Adeli "Closing the gaps in pediatric reference intervals: the CALIPER initiative" Clin Biochem (2011) 10.1016/j.clinbiochem.2011.02.017
[9]
Zierk "Blood counts in adult and elderly individuals: defining the norms over eight decades of life" Br J Haematol (2020) 10.1111/bjh.16430
[10]
Haeckel "Review of potentials and limitations of indirect approaches for estimating reference limits/intervals of quantitative procedures in laboratory medicine" J Lab Med (2021) 10.1515/labmed-2020-0131
[11]
Ammer "refineR: A novel algorithm for reference interval estimation from real-world data" Sci Rep (2021) 10.1038/s41598-021-95301-2
[12]
An Analysis of Transformations

G. E. P. Box, D. R. Cox

Journal of the Royal Statistical Society Series B:... 1964 10.1111/j.2517-6161.1964.tb00553.x
[13]
Farrell "Indirect reference intervals: harnessing the power of stored laboratory data" Clin Biochem Rev (2019)
[14]
[15]
Ammer
[16]
Ichihara "Determination of reference intervals for 13 plasma proteins based on IFCC international reference preparation (CRM470) and NCCLS proposed guideline (C28-P, 1992): trial to select reference individuals by results of screening tests and application of maxim" J Clin Lab Anal (1996) 10.1002/(sici)1098-2825(1996)10:2<110::aid-jcla9>3.0.co;2-g
[17]
Ichihara "An appraisal of statistical procedures used in derivation of reference intervals" Clin Chem Lab Med (2010) 10.1515/cclm.2010.319
[18]
Haeckel "The importance of correct stratifications when comparing directly and indirectly estimated reference intervals" Clin Chem Lab Med (2021) 10.1515/cclm-2021-0353
[19]
International Organization for Standardization. ISO 15189: Medical laboratories—requirements for quality and competence. Geneva (Switzerland): International Organization for Standardization; 2012.
[20]
Jones "Validating common reference intervals in routine laboratories" Clin Chim Acta (2014) 10.1016/j.cca.2013.10.005
[21]
Doyle "Verifying clinically derived reference intervals for daily excretion rates of fractionated metanephrines using modern indirect reference interval models" Am J Clin Pathol (2021) 10.1093/ajcp/aqab006
Metrics
38
Citations
21
References
Details
Published
Jan 04, 2023
Vol/Issue
8(1)
Pages
84-91
License
View
Cite This Article
Tatjana Ammer, André Schützenmeister, Christopher M Rank, et al. (2023). Estimation of Reference Intervals from Routine Data Using the refineR Algorithm—A Practical Guide. The Journal of Applied Laboratory Medicine, 8(1), 84-91. https://doi.org/10.1093/jalm/jfac101