journal article Sep 19, 2013

A comparison of single particle tracking and temporal image correlation spectroscopy for quantitative analysis of endosome motility

Journal of Microscopy Vol. 252 No. 2 pp. 169-188 · Wiley
View at Publisher Save 10.1111/jmi.12080
Abstract
SummarySingle particle tracking (SPT) is becoming a standard method to extract transport parameters from time‐lapse image sequences of fluorescent vesicles in living cells. Another method to obtain these data is temporal image correlation spectroscopy (TICS), but this method is less often used for measurement of intracellular vesicle transport. Here, we present an extensive comparison of SPT and TICS. First we examine the effect of photobleaching, shading and noise on SPT and TICS analysis using simulated image sequences. To this end, we developed a simple photophysical model, which relates spatially varying illumination intensity to the bleaching propensity and fluorescence intensity of the moving particles. We found that neither SPT nor TICS are affected by photobleaching per se, but the transport parameters obtained by both methods are sensitive to the signal‐to‐noise ratio. In addition, the number of obtained trajectories in SPT is affected by noise. Diffusion constants determined by TICS are significantly overestimated when large immobile fluorescent structures are present in the image sequences, while the opposite is true for SPT. To improve the performance of both techniques, we compare three different methods for image denoising. Appropriate denoising significantly reduced the effect of noise and of immobile structures on both methods. Shape fluctuations of simulated particles had a more pronounced effect on TICS than on SPT analysis. In denoised images of fluorescent beads or cytosolic vesicles containing fluorescent protein NPC2 in human skin fibroblast cells, the transport parameters acquired by SPT and TICS were comparable emphasizing the value of both analysis methods.
Topics

No keywords indexed for this article. Browse by subject →

References
65
[2]
Statistics of camera-based single-particle tracking

Andrew J. Berglund

Physical Review E 10.1103/physreve.82.011917
[4]
Brown C.M. "An image correlation analysis of the distribution of clathrin associated adaptor protein (AP‐2) at the plasma membrane" J. Cell Sci. (1998) 10.1242/jcs.111.2.271
[8]
An Ultrasensitive Bacterial Motor Revealed by Monitoring Signaling Proteins in Single Cells

Philippe Cluzel, Michael Surette, Stanislas Leibler

Science 10.1126/science.287.5458.1652
[10]
Methods of Digital Video Microscopy for Colloidal Studies

John C. Crocker, David G. Grier

Journal of Colloid and Interface Science 10.1006/jcis.1996.0217
[14]
Gonzalez R.C. (2007)
[22]
Robust single-particle tracking in live-cell time-lapse sequences

Khuloud Jaqaman, Dinah Loerke, Marcel Mettlen et al.

Nature Methods 10.1038/nmeth.1237
[25]
Sampling Effects, Noise, and Photobleaching in Temporal Image Correlation Spectroscopy

David L. Kolin, Santiago Costantino, Paul W. Wiseman

Biophysical Journal 10.1529/biophysj.105.072322
[29]
Lim J.S. (1990)
[32]
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy

Douglas Magde, Elliot Elson, W. W. Webb

Physical Review Letters 10.1103/physrevlett.29.705
[35]
Meijering E. (2012)
[42]
Pentchev P.G. "Group C Niemann‐Pick disease: faulty regulation of low‐density lipoprotein uptake and cholesterol storage in cultured fibroblasts" FASEB J. 10.1096/fasebj.1.1.3609608
[44]
Single particle tracking. Analysis of diffusion and flow in two-dimensional systems

H. Qian, M.P. Sheetz, E.L. Elson

Biophysical Journal 10.1016/s0006-3495(91)82125-7
[47]
Saxton M.J. (2009)

Showing 50 of 65 references

Metrics
15
Citations
65
References
Details
Published
Sep 19, 2013
Vol/Issue
252(2)
Pages
169-188
License
View
Cite This Article
F.W. LUND, D. WÜSTNER (2013). A comparison of single particle tracking and temporal image correlation spectroscopy for quantitative analysis of endosome motility. Journal of Microscopy, 252(2), 169-188. https://doi.org/10.1111/jmi.12080