journal article Oct 18, 2016

Spurious reticulocyte profiles in a dog with babesiosis

Veterinary Clinical Pathology Vol. 45 No. 4 pp. 594-597 · Wiley
View at Publisher Save 10.1111/vcp.12395
Abstract
AbstractA 9‐year‐old, female Maltese dog was referred to the Veterinary School of Toulouse with a 2‐day history of anorexia and weakness. On clinical examination, the dog had hyperthermia (39.7°C), abdominal discomfort, and polypnea. Significant laboratory findings included pigmenturia, hyperbilirubinemia, hypercreatininemia, hyperfibrinogenemia, abnormal Snap canine pancreas‐specific lipase, and pancytopenia with a nonregenerative anemia. A peripheral blood smear revealed numerous intraerythrocytic large Babesia but no polychromasia. There was a discrepancy between the absolute automated reticulocyte count (Sysmex reticulocyte count: 60 × 109/L; RI 19.4–150.1 × 109/L) and the manual reticulocyte count (3.6 × 109/L) as well as the absence of polychromasia. The optical red blood cell scattergram showed an abnormal isolated reticulocyte cluster at the location of low‐fluorescence ratio cells. These findings were interpreted as erythrocytes parasitized by large Babesia. The discrepancy between the Sysmex reticulocyte count and the manual reticulocyte count has been reported previously in people with falciparum malaria and numerous intra‐erythrocytic Plasmodium falciparum organisms. This spurious reticulocyte profile and reticulocyte count were observed with the Sysmex XT‐2000iV and the ProCyte using the same fluorescent dye polymethine but not with the LaserCyte using new methylene blue which does not stain Babesia organisms on a blood smear performed for manual reticulocyte counting.
Topics

No keywords indexed for this article. Browse by subject →

References
16
[8]
Espagnol I "Heinz bodies interfere with automated reticulocyte count" Haematologica (1999)
[10]
Ghevaert C "Laboratory evaluation of the Coulter STKS reticulocyte method in a children's hospital" Lab Hematol (1997)
[11]
Pappas AA "Reticulocyte counting by flow cytometry. A comparison with manual methods" Ann Clin Lab Sci (1992)
[12]
Oyamatsu T "Automated measurement of reticulocyte count by flow cytometry. II: analysis of the blood containing abnormal erythrocytes or giant platelets" Rinsho Byori (1989)
Metrics
10
Citations
16
References
Details
Published
Oct 18, 2016
Vol/Issue
45(4)
Pages
594-597
License
View
Cite This Article
Laetitia Piane, Marie‐Laure Théron, Marcel Aumann, et al. (2016). Spurious reticulocyte profiles in a dog with babesiosis. Veterinary Clinical Pathology, 45(4), 594-597. https://doi.org/10.1111/vcp.12395