journal article Feb 01, 1998

Experimental determination of the convolution kernel for the study of the spatial response of a detector

Medical Physics Vol. 25 No. 2 pp. 202-207 · Wiley
Abstract
One of the most important parameters in the characterization of a detector is its spatial convolution kernel. This kernel contains all of the information about the influence that the detector size has on the measured beam profile. In this paper we present an experimental method for the determination of the spatial convolution kernel for commonly used detectors that are employed in the x‐ray profile measurement: diode, and ionization minichamber. Our work is based on first assuming a step function pattern on a photographic film is known and is a perfect step function. The kernel of the densitometer system was then derived from the deconvolution of the scanned profile to the step function. Next a film was exposed to a penumbra area of an x‐ray beam from a linac. The film was scanned using the same densitometer. The “real profile” that emerges from a linear accelerator was derived by the deconvolution of the scanned profile using the now known kernel of the film densitometer. Under the same irradiation condition the x‐ray profile was measured with other detectors and with this information we obtained the convolution kernels for these detectors by solving numerically their basic convolution integrals. The results show that the Gaussian convolution kernel is the most consistent with the measurements. The best numerical values for the FWHM of the kernels are 1.1 mm, 2.2 mm, and 5.4 mm for densitometer, diode, and minichamber, respectively.
Topics

No keywords indexed for this article. Browse by subject →

References
12
[2]
The effect of detector size to the broadening of the penumbra—a computer simulated study

Kai‐Siung Chang, Fang‐Fang Yin, Kai‐Wen Nie

Medical Physics 10.1118/1.597724
[7]
R. N. Bracewell The Fourier Transform and its Applications(McGraw‐Hill New York 1986).
[8]
Scanditronix RT Divisionen (private communication).
[9]
Daniel Skerhut and Rudolf Klepper “Verfahren zur Dosiskalibrierung in der Filmdosimetrie ohne externe Eichung ” inMedizinische Physik 1993 Abstract book of the yearly Congress of the German Association of Medical Physics Bonn 1993 edited by G. Miller and J. Erb.
[10]
An Algorithm for Least-Squares Estimation of Nonlinear Parameters

Donald W. Marquardt

Journal of the Society for Industrial and Applied... 10.1137/0111030
[11]
Siegmund Brandt Statistical and Computational Methods in Data Analysis(North‐Holland Amsterdam 1970).
[12]
G. Rikner “Silicon diodes as detectors in relative dosimetry of photon electron and proton radiation fields ” Ph.D. thesis Uppsala University Sweden 1983.
Cited By
75
Metrics
75
Citations
12
References
Details
Published
Feb 01, 1998
Vol/Issue
25(2)
Pages
202-207
License
View
Cite This Article
F. Garcı́a‐Vicente, J. M. Delgado, C. Peraza (1998). Experimental determination of the convolution kernel for the study of the spatial response of a detector. Medical Physics, 25(2), 202-207. https://doi.org/10.1118/1.598182