journal article Sep 04, 2014

Fire Behaviour of Circular Concrete Columns with Restrained Thermal Elongation

View at Publisher Save 10.3151/jact.12.289
Topics

No keywords indexed for this article. Browse by subject →

References
22
[1]
1) Ali, F., Nadjai, A., Silcock, G. and Abu-Tair, A., (2004). “Outcomes of a major research on fire resistance of concrete columns.” <i>Fire Safety Journal</i>, 39, 433-445. 10.1016/j.firesaf.2004.02.004
[2]
2) Correia, A. M. and Rodrigues, J. P. C., (2011). “Fire resistance of partially encased steel columns with restrained thermal elongation.” <i>Journal of Constructional Steel Research</i>, 67, 593-601. 10.1016/j.jcsr.2010.12.002
[3]
3) Correia, A. M. and Rodrigues, J. P. C., (2012). “Fire resistance of steel columns with restrained thermal elongation.” <i>Fire Safety Journal</i>, 50, 1-11. 10.1016/j.firesaf.2011.12.010
[4]
4) Correia, A. M., Rodrigues, J. P. C. and Silva, V. P., (2011). “A simplified calculation method for temperature evaluation of steel columns embedded in walls.” <i>Fire and Materials</i>, 35, 431-441. 10.1002/fam.1063
[5]
5) Dotreppe, J.-C., Franssen, J.-M., Bruls, A., Baus, R., Vandevelde, P., Minne, R., Van Nieuwenburg, D. and Lambotte, H., (1997). “Experimental research on the determination of the main parameters affecting the behaviour of reinforced concrete columns under fire conditions.” <i>Magazine of Concrete Research</i>, 49 (179), 117-27. 10.1680/macr.1997.49.179.117
[6]
6) EN 1992-1-1, (2003). “<i>Design of concrete structures – Part 1-1: General rules and rules for buildings</i>.” European Committee for Standardization (CEN), Brussels, Belgium.
[7]
7) EN 1992-1-2, (2003). “<i>Design of concrete structures – Part 1-2: General rules – Structural fire design</i>.” European Committee for Standardization (CEN), Brussels, Belgium.
[8]
8) EN1993-1.1, (2004). “<i>Design of steel structures – Part 1-1: General rules and rules for buildings</i>.” European Committee for Standardization (CEN), Brussels, Belgium.
[9]
9) Franssen, J.-M. and Dotreppe, J.-C., (2003). “Fire tests and calculation methods for circular concrete columns.” <i>Fire Technology</i>, 39, 89-97. 10.1023/a:1021783311892
[10]
10) ISO 834-1, (1999). “<i>Fire-resistance tests – Elements of building construction – Part 1: General requirements</i>.” <i>International Organization for Standardization</i>, Genève, Switzerland.
[11]
11) Klingsch, W., Haksever, A. and Walter, R., (1997). “<i>Brandversuche an Stahlbetonstützen, Versuchsergebnisse und Numerische Analyse</i>.” Sonderforschungsbereich 148, Brandverhalten von Bauteilen, Arbeitsbericht, 1975-1977, teil I, TU Braunschweig, (in German).
[12]
12) Kodur, V. K. R., Wang, T. C. and Cheng, F. P., (2004). “Predicting the fire resistance behaviour of high strength concrete columns.” <i>Cement and Concrete Composites</i>, 26, 141-53. 10.1016/s0958-9465(03)00089-1
[13]
13) Lie, T. T. and Lin, T. D., (1985). “Influence of restraint on fire performance of reinforced concrete columns.” In: Proceedings of the first international symposium fire safety science, 291-300.
[14]
14) Lie, T. T., Lin, T. D., Allen, D. E. and Abrams, M. S., (1984). “<i>Fire resistance of reinforced concrete columns</i>.” National Research Council of Canada, Division of Building Research, NRCC - 23065, Ottawa.
[15]
15) Lin, T. D., Zwiers, R. I., Burg, R. G., Lie, T. T. and McGrat, R. J., (1992). “<i>Fire resistance of reinforced concrete columns</i>.” Research and Development Bulletin RD101B, Portland Cement Association.
[16]
16) Martins, A. M. B. and Rodrigues, J. P. C., (2010). “Fire resistance of reinforced concrete columns with elastically restrained thermal elongation.” <i>Engineering Structures</i>, 32, 3330-3337. 10.1016/j.engstruct.2010.07.005
[17]
17) NP-EN 206-1, (2007). “<i>Concrete. Specification, performance, production and conformity</i>.” European Standard (Portuguese version). European Committee for Standardization (CEN), Brussels, Belgium.
[18]
18) Pires, T. A. C., Rodrigues, J. P. C. and Silva, J. J. R., (2012). “Fire resistance of concrete filled circular hollow columns with restrained thermal elongation.” <i>Journal of Constructional Steel Research</i>, 77, 82-94. 10.1016/j.jcsr.2012.03.028
[19]
19) Rodrigues, J. P. C. and Laím, L. M., (2011). “Behaviour of Perfobond shear connectors at high temperatures.” <i>Engineering Structures</i>, 33, 2744-2753. 10.1016/j.engstruct.2011.05.004
[20]
20) Rodrigues, J. P. C., Laím, L. M. and Correia, A. M., (2010). “Behaviour of fiber reinforced concrete columns in fire.” <i>Composite Structures</i>, 92, 1263-1268. 10.1016/j.compstruct.2009.10.029
[21]
21) Wu, B. and Xu, Y., (2009). “Behavior of axially-and-rotationally restrained concrete columns with ‘+’-shaped cross section and subjected to fire.” <i>Fire Safety Journal</i>, 44, 212-218. 10.1016/j.firesaf.2008.07.003
[22]
22) Xu, Y. and Wu, B., (2009). “Fire resistance of reinforced concrete columns with L-,T- and ‘+’-shaped cross-sections.” <i>Fire Safety Journal</i>, 44, 869-880. 10.1016/j.firesaf.2009.04.002
Metrics
11
Citations
22
References
Details
Published
Sep 04, 2014
Vol/Issue
12(9)
Pages
289-298
Cite This Article
João Paulo C. Rodrigues, Luís M. Laím, Manfred Korzen (2014). Fire Behaviour of Circular Concrete Columns with Restrained Thermal Elongation. Journal of Advanced Concrete Technology, 12(9), 289-298. https://doi.org/10.3151/jact.12.289
Related

You May Also Like