journal article Open Access Mar 06, 2019

Accuracy and Inter-Unit Reliability of Ultra-Wide-Band Tracking System in Indoor Exercise

Applied Sciences Vol. 9 No. 5 pp. 939 · MDPI AG
View at Publisher Save 10.3390/app9050939
Abstract
The purpose of this study was to assess the accuracy of positional data and the inter-unit reliability of an ultra-wide-band (UWB) tracking system. Four well-trained males performed five courses designed for the analysis of x- and y-coordinate accuracy analysis, specifically related to the positional distance variation between the UWB data and the fixed reference lines of a basketball court. This was achieved using geographic information system (GIS) mapping software that calculated, for each interval and participant, the distance from the main axis of displacement and from the opposite side of the court each 0.5 s (x and y coordinate). The accuracy of the results was satisfactory, with a mean absolute error of all estimations for the x-position of 5.2 ± 3.1 cm and for the y-position of 5.8 ± 2.3 cm. Regarding inter-unit reliability, the intra-class correlation coefficient (ICC) value was high for the x-coordinate (0.65) and very high for the y-coordinate (0.85). The main findings of the study were: (i) The accuracy of UWB tracking systems can be considered suitable for practical applications in sport analyses; (ii) position estimations are very precise and acceptable for tactical analyses; (iii) the error of the position estimations does not change significantly across different courses; and (iv) the use of different devices does not significantly affect the measurement error.
Topics

No keywords indexed for this article. Browse by subject →

References
36
[1]
Leser "Local Positioning Systems in (Game) Sports" Sensors (2011) 10.3390/s111009778
[2]
Coutts "The validity and reliability of a global positioning satellite system device to assess speed and repeated sprint ability (RSA) in athletes" J. Sci. Med. Sport (2010) 10.1016/j.jsams.2009.02.005
[3]
Integrating different tracking systems in football: multiple camera semi-automatic system, local position measurement and GPS technologies

Martin Buchheit, Adam Allen, Tsz Kit Poon et al.

Journal of Sports Sciences 2014 10.1080/02640414.2014.942687
[4]
Frencken "Soccer-specific accuracy and validity of the local position measurement (LPM) system" J. Sci. Med. Sport (2010) 10.1016/j.jsams.2010.04.003
[5]
Ogris "Accuracy of the LPM tracking system considering dynamic position changes" J. Sports Sci. (2012) 10.1080/02640414.2012.712712
[6]
Leser "Accuracy of an UWB-based position tracking system used for time-motion analyses in game sports" Eur. J. Sport Sci. (2014) 10.1080/17461391.2014.884167
[7]
Rhodes "The validity and reliability of a novel indoor player tracking system for use within wheelchair court sports" J. Sports Sci. (2014) 10.1080/02640414.2014.910608
[8]
Valter "Validation of Prozone®: A new video-based performance analysis system" Int. J. Perform. Anal. Sport (2006) 10.1080/24748668.2006.11868359
[9]
Barris "A review of vision-based motion analysis in sport" Sports Med. (2008) 10.2165/00007256-200838120-00006
[10]
Carling, C., Reilly, T., and Williams, A.M. (2009). Performance Assessment for Field Sports, Routledge. 10.4324/9780203890691
[11]
Buchheit, M., and Simpson, B.M. (2016). Player Tracking Technology: Half-Full or Half-Empty Glass?. Int. J. Sports Physiol. Perform., 1–23.
[12]
"Accuracy, intra- and inter-unit reliability, and comparison between GPS and UWB-based position-tracking systems used for time–motion analyses in soccer" Eur. J. Sport Sci. (2018) 10.1080/17461391.2018.1427796
[13]
Castellano "Evaluation of Research Using Computerised Tracking Systems (Amisco (R) and Prozone (R)) to Analyse Physical Performance in Elite Soccer: A Systematic Review" Sports Med. (2014) 10.1007/s40279-014-0144-3
[14]
Scott "The validity and reliability of global positioning systems in team sport: A brief review" J. Strength Cond. Res. (2015)
[15]
Malone "Unpacking the Black Box: Applications and Considerations for Using GPS Devices in Sport" Int. J. Sports Physiol. Perform. (2017) 10.1123/ijspp.2016-0236
[16]
Coutts "Validity and reliability of GPS devices for measuring movement demands of team sports" J. Sci. Med. Sport (2010) 10.1016/j.jsams.2008.09.015
[17]
Waldron "Concurrent validity and test–retest reliability of a global positioning system (GPS) and timing gates to assess sprint performance variables" J. Sports Sci. (2011) 10.1080/02640414.2011.608703
[18]
Luteberget, L.S., Spencer, M., and Gilgien, M. (2018). Validity of the Catapult ClearSky T6 Local Positioning System for Team Sports Specific Drills, in Indoor Conditions. Front. Physiol., 9. 10.3389/fphys.2018.00115
[19]
Sathyan "Validity and reliability of a radio positioning system for tracking athletes in indoor and outdoor team sports" Behav. Res. Methods (2012) 10.3758/s13428-012-0192-2
[20]
Begon "Computation of the 3D kinematics in a global frame over a 40m-long pathway using a rolling motion analysis system" J. Biomech. (2009) 10.1016/j.jbiomech.2009.08.020
[21]
Stevens "Measuring Acceleration and Deceleration in Soccer-Specific Movements Using a Local Position Measurement (LPM) System" Int. J. Sports Physiol. Perform. (2014) 10.1123/ijspp.2013-0340
[22]
Reijne "Accuracy of human motion capture systems for sport applications; state of the art review" Eur. J. Sport Sci. (2018) 10.1080/17461391.2018.1463397
[23]
Pittet, S., Renaudin, V., Merminod, B., and Kasser, M. (2008). UWB and MEMS Based Indoor Navigation. J. Navig., 61. 10.1017/s0373463308004797
[24]
Sczyslo, S., Schroeder, J., Galler, S., and Kaiser, T. (2008, January 10–12). Hybrid localization using UWB and inertial sensors. Proceedings of the 2008 IEEE International Conference on Ultra-Wideband, Hannover, Germany. 10.1109/icuwb.2008.4653423
[25]
Hirokawa "A Low-Cost Tightly Coupled GPS/INS for Small UAVs Augmented with Multiple GPS Antennas" Navigation (2009) 10.1002/j.2161-4296.2009.tb00442.x
[26]
Hol, J. (2011). Sensor Fusion and Calibration of Inertial Sensors, Vision, Ultra-Wideband and GPS, Department of Electrical Engineering, Linköping University.
[27]
Hol, J.D., Schon, T.B., and Gustafsson, F. (2010, January 20–23). Ultra-wideband calibration for indoor positioning. Proceedings of the 2010 IEEE International Conference on Ultra-Wideband, Nanjing, China. 10.1109/icuwb.2010.5616867
[28]
Bastida Castillo, A., Gómez Carmona, C.D., Pino Ortega, J., and de la Cruz Sánchez, E. (2017). Validity of an inertial system to measure sprint time and sport task time: A proposal for the integration of photocells in an inertial system. Int. J. Perform. Anal. Sport, 1–9. 10.1080/24748668.2017.1374633
[29]
Progressive Statistics for Studies in Sports Medicine and Exercise Science

WILLIAM G. HOPKINS, Stephen W. Marshall, Alan M. Batterham et al.

Medicine & Science in Sports & Exercise 2009 10.1249/mss.0b013e31818cb278
[30]
Castellano "Reliability and Accuracy of 10 GPS Devices for Short-Distance Exercise" J. Sports Sci. Med. (2011)
[31]
Duffield "Accuracy and reliability of GPS devices for measurement of movement patterns in confined spaces for court-based sports" J. Sci. Med. Sport (2010) 10.1016/j.jsams.2009.07.003
[32]
Gray "Validity and reliability of GPS for measuring distance travelled in field-based team sports" J. Sports Sci. (2010) 10.1080/02640414.2010.504783
[33]
Johnston "The validity and reliability of 5-hz global positioning system units to measure team sport movement demands" J. Strength Cond. Res. (2012) 10.1519/jsc.0b013e318225f161
[34]
Validity and Interunit Reliability of 10 Hz and 15 Hz GPS Units for Assessing Athlete Movement Demands

Richard J. Johnston, Mark L. Watsford, Stephen J. Kelly et al.

The Journal of Strength and Conditioning Research 2014 10.1519/jsc.0000000000000323
[35]
Beato, M., Bartolini, D., Ghia, G., and Zamparo, P. (2016). Accuracy of a 10 Hz GPS Unit in Measuring Shuttle Velocity Performed at Different Speeds and Distances (5–20 M). J. Hum. Kinet., 54. 10.1515/hukin-2016-0031
[36]
Janssen "Validity and reliability of intra-stroke kayak velocity and acceleration using a GPS-based accelerometer" Sports Biomech. (2010) 10.1080/14763141003690229