journal article Open Access Nov 07, 2020

Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids

Sensors Vol. 20 No. 21 pp. 6352 · MDPI AG
View at Publisher Save 10.3390/s20216352
Abstract
Non-invasive healthcare technologies are an important part of research and development nowadays due to the low cost and convenience offered to both healthcare receivers and providers. This work overviews the recent advances in the field of non-invasive electrochemical biosensors operating in secreted human physiological fluids, viz. tears, sweat, saliva, and urine. Described electrochemical devices are based on different electrochemical techniques, viz. amperometry, coulometry, cyclic voltammetry, and impedance spectroscopy. Challenges that confront researchers in this exciting area and key requirements for biodevices are discussed. It is concluded that the field of non-invasive sensing of biomarkers in bodily fluid is highly convoluted. Nonetheless, if the drawbacks are appropriately addressed, and the pitfalls are adroitly circumvented, the approach will most certainly disrupt current clinical and self-monitoring practices.
Topics

No keywords indexed for this article. Browse by subject →

References
188
[1]
Yamani:, A.Z., Alqahtani, F.M., Alshahrani, N.S., Alzamanan, R.M., Aslam, N., and Algherairy, A.S. (2019, January 10–11). A proposed noninvasive point-of-care technique for measuring hemoglobin concentration. Proceedings of the 2019 International Conference on Computer and Information Sciences (ICCIS), Aljouf, Saudi Arabia. 10.1109/iccisci.2019.8716418
[2]
Olarte, O., Chilo, J., Pelegri-Sebastia, J., Barbe, K., and Van Moer, W. (2013, January 3–7). Glucose detection in human sweat using an electronic nose. Proceedings of the 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Osaka, Japan. 10.1109/embc.2013.6609787
[3]
Okutucu "Molecularly imprinted polymers for separation of various sugars from human urine" Talanta (2011) 10.1016/j.talanta.2011.09.043
[4]
Aydin "A comparison of ghrelin, glucose, alpha-amylase and protein levels in saliva from diabetics" J. Biochem. Mol. Biol. (2007)
[5]
Yao "A contact lens with embedded sensor for monitoring tear glucose level" Biosens. Bioelectron. (2011) 10.1016/j.bios.2010.12.042
[6]
Moyer "Correlation between sweat glucose and blood glucose in subjects with diabetes" Diabetes Technol. (2012) 10.1089/dia.2011.0262
[7]
Morris "Correlation between plasma and urine glucose in diabetes" Ann. Intern. Med. (1981) 10.7326/0003-4819-94-4-469
[8]
Puttaswamy "Correlation between salivary glucose and blood glucose and the implications of salivary factors on the oral health status in type 2 diabetes mellitus patients" J. Int. Soc. Prev. Community Dent. (2017) 10.4103/2231-0762.200703
[9]
Lane "Tear glucose dynamics in diabetes mellitus" Curr. Eye Res. (2006) 10.1080/02713680600976552
[10]
Howell "Diagnostic technologies - X-rays, electrocardiograms, and cat-scans" South. Calif. Law Rev. (1991)
[11]
Fye "A history of the origin, evolution and impact of electrocardiography" Am. J. Cardiol. (1994) 10.1016/0002-9149(94)90135-x
[12]
Bonetti "Noninvasive identification of patients with early coronary atherosclerosis by assessment of digital reactive hyperemia" J. Am. Coll. Cardiol. (2004) 10.1016/j.jacc.2004.08.062
[13]
Assessment of fat-free mass using bioelectrical impedance measurements of the human body

HC Lukaski, PE Johnson, WW Bolonchuk et al.

The American Journal of Clinical Nutrition 1985 10.1093/ajcn/41.4.810
[14]
The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status Monitoring and Diagnosis of Diseases

Sami Khalil, Mas Mohktar, Fatimah Ibrahim

Sensors 2014 10.3390/s140610895
[15]
Barker "Continuous noninvasive hemoglobin monitoring: A measured response to a critical review" Anesth. Analg. (2016) 10.1213/ane.0000000000000605
[16]
Taylor "The current status of pulse oximetry—Clinical value of continuous noninvasive oxygen-saturation monitoring" Anaesthesia (1986) 10.1111/j.1365-2044.1986.tb12922.x
[17]
Tierney "Clinical evaluation of the GlucoWatch (R) biographer: A continual, non-invasive glucose monitor for patients with diabetes" Biosens. Bioelectron. (2001) 10.1016/s0956-5663(01)00189-0
[18]
Caduff "Non-invasive glucose monitoring in patients with diabetes: A novel system based on impedance spectroscopy" Biosens. Bioelectron. (2006) 10.1016/j.bios.2006.01.031
[19]
Ahrens, T., and Tucker, K. (1999). Pulse Oximetry, Department of Critical Care, Barnes-Jewish Hospital. United States FIELD Citation. 10.1016/s0899-5885(18)30180-1
[20]
Smith, J.L. (2020). The Pursuit of Noninvasive Glucose: “Hunting the deceitful Turkey” Seventh Edition, NIVG Consulting LLC.
[21]
Yuan "Research on improving the accuracy of near infrared non-invasive hemoglobin detection" Infrared Phys. Technol. (2015) 10.1016/j.infrared.2015.06.009
[22]
Adel "Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses" J. Clin. Monit. Comput. (2018) 10.1007/s10877-018-0101-z
[23]
Wearable flexible sweat sensors for healthcare monitoring: a review

Michael Chung, Giuseppino Fortunato, Norbert Radacsi

Journal of The Royal Society Interface 2019 10.1098/rsif.2019.0217
[24]
Bandodkar "Wearable Sensors for Biochemical Sweat Analysis" Annu. Rev. Anal. Chem. (2019) 10.1146/annurev-anchem-061318-114910
[25]
Chambers "Biosensor recognition elements" Curr. Issues Mol. Biol. (2008)
[26]
Murube "Basal, reflex, and psycho-emotional tears" Ocul. Surf. (2009) 10.1016/s1542-0124(12)70296-3
[27]
Berman, E.R. (1991). Biochemistry of the Eye, Plenum Press. 10.1007/978-1-4757-9441-0
[28]
Glasius "Collection method dependent concentrations of some metabolites in human tear fluid, with special reference to glucose in hyperglycaemic conditions" Graefe’s Arch. Clin. Exp. Ophthalmol. (1977) 10.1007/bf00496763
[29]
Phillips, A. (2007). Contact Lenses, Elsevier.
[30]
Agarwal, S., Agarwal, A., Buratto, L., Apple, D.J., and Ali, J.L. (2002). Textbook of Ophthalmology, Jaypee Brothers Publishers.
[31]
Farandos "Contact lens sensors in ocular diagnostics" Adv. Healthc. Mater. (2015) 10.1002/adhm.201400504
[32]
Nichols "Investigation of the human tear film proteome using multiple proteomic approaches" Mol. Vis. (2008)
[33]
Li "Antibody protein array analysis of the tear film cytokines" Optom. Vis. Sci. Off. Publ. Am. Acad. Optom. (2008) 10.1097/opx.0b013e3181824e20
[34]
Markoulli "Validation of the flush method as an alternative to basal or reflex tear collection" Curr. Eye Res. (2011) 10.3109/02713683.2010.542867
[35]
Sack "Antibody array characterization of inflammatory mediators in allergic and normal tears in the open and closed eye environments" Exp. Eye Res. (2007) 10.1016/j.exer.2007.07.004
[36]
Shum "Functional modular contact lens" Proc. SPIE (2009) 10.1117/12.827720
[37]
Parviz "For your eye only" IEEE Spectr. (2009) 10.1109/mspec.2009.5210042
[38]
Fang "A high-performance glucose biosensor based on monomolecular layer of glucose oxidase covalently immobilised on indium-tin oxide surface" Biosens. Bioelectron. (2003) 10.1016/s0956-5663(03)00133-7
[39]
Yao, H., Afanasiev, A., Lahdesmaki, I., and Parviz, B.A. (2011, January 23–27). A dual microscale glucose sensor on a contact lens, tested in conditions mimicking the eye. Proceedings of the 2011 IEEE 24th International Conference on Micro Electro Mechanical Systems, Cancun, Mexico. 10.1109/memsys.2011.5734353
[40]
Liao "A 3-mu W CMOS glucose sensor for wireless contact-lens tear glucose monitoring" IEEE J. Solid-St. Circ. (2012) 10.1109/jssc.2011.2170633
[41]
Yao, H., Liao, Y., Lingley, A.R., Afanasiev, A., Lahdesmaki, I., Otis, B.P., and Parviz, B.A. (2012). A contact lens with integrated telecommunication circuit and sensors for wireless and continuous tear glucose monitoring. J. Micromech. Microeng., 22. 10.1088/0960-1317/22/7/075007
[42]
Morse, A. (2014). Novartis and Google to Work on Smart Contact Lenses, The Wall Steeet Journal.
[43]
Thomas "A contact lens with an integrated lactate sensor" Sens. Actuators B (2012) 10.1016/j.snb.2011.12.049
[44]
Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment

Ming Xing Chu, Kumiko Miyajima, Daishi Takahashi et al.

Talanta 2011 10.1016/j.talanta.2010.10.055
[45]
Chu "Biomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents" Biomed Microdevices (2011) 10.1007/s10544-011-9530-x
[46]
Patel "Flexible three-dimensional electrochemical glucose sensor with improved sensitivity realized in hybrid polymer microelectromechanical systems technique" J. Diabetes Sci. Technol. (2011) 10.1177/193229681100500503
[47]
Andoralov "Flexible micro(bio)sensors for quantitative analysis of bioanalytes in a nanovolume of human lachrymal liquid" Anal. Bioanal. Chem. (2013) 10.1007/s00216-013-6756-x
[48]
Malon "Saliva-Based Biosensors: Noninvasive Monitoring Tool for Clinical Diagnostics" Biomed Res. Int. (2014) 10.1155/2014/962903
[49]
Ilea, A., Andrei, V., Feurdean, C.N., Babtan, A.M., Petrescu, N.B., Campian, R.S., Bosca, A.B., Ciui, B., Tertis, M., and Sandulescu, R. (2019). Saliva, a Magic Biofluid Available for Multilevel Assessment and a Mirror of General Health-A Systematic Review. Biosensors, 9. 10.3390/bios9010027
[50]
Lee "Saliva: An emerging biofluid for early detection of diseases" Am. J. Dent. (2009)

Showing 50 of 188 references

Related

You May Also Like

SECOND: Sparsely Embedded Convolutional Detection

Yan Yan, Yuyin Mao · 2018

2,824 citations

Metal Oxide Gas Sensors: Sensitivity and Influencing Factors

Chengxiang Wang, Longwei Yin · 2010

2,595 citations

Machine Learning in Agriculture: A Review

Konstantinos Liakos, Patrizia Busato · 2018

2,472 citations

Wearable Electronics and Smart Textiles: A Critical Review

Matteo Stoppa, Alessandro Chiolerio · 2014

1,823 citations