Abstract
Introduction:
Air conditioning (AC) has become a widespread necessity in modern environments, especially in urban and industrial
areas. Despite its benefits in providing comfort, concerns are rising regarding the long-term effects of AC exposure on
respiratory health. This study aims to compare pulmonary function test (PFT) results between individuals regularly exposed
to air conditioning and those not exposed to it, to better understand the potential effects on lung function.
 Aim and Objectives:
This paper was intended to evaluate the impact of air conditioning on lung function by comparing PFT outcomes of
people who use air conditioning and those who do not. The first objective was to determine if respiratory health is affected
after exposure to air conditioning.
 Methods:
A cross-sectional comparative study was conducted for a period of 2.5 years. Two hundred participants from Kalol,
Gandhinagar, Gujarat, 5 years of study. The participants were categorized into two groups: AC users were defined as those
people who had used air conditioning for more than six hours a day for at least one year while non-AC users were those who
had no regular exposure to AC. Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEV1), Peak
Expiratory Flow Rate (PEFR) and Forced Expiratory Flow 25-75% (FEF25-75%) pulmonary function tests were conducted
using Portable Spirometer (Helios 702). The data was analyzed by unpaired t-test and chi-square test.
 Results:
Results demonstrated significant reductions in lung function among AC users compared to non-AC users. Predicted
FVC was significantly lower in AC users (2.31 ± 0.91 L) compared to non-AC users (3.37 ± 0.92 L, p < 0.0001). Similarly,
predicted PEFR, FEF25-75% were significantly lower in AC users (p = 0.04 for both parameters). No significant differences
were found in FEV1 or FEV1/FVC ratio among 2 groups (p = 0.41 and 0.89, respectively). The findings suggest that
prolonged AC exposure can reduce lung volumes and affect small airway function.
 Conclusion:
This study demonstrates that prolonged exposure to air conditioning may adversely affect lung volumes and airflow,
particularly in the smaller airways. No significant differences were observed in FEV1 and FEV1/FVC ratio, the significant reductions in FVC, FEFR, and FEF25-75% highlight the potential respiratory risks associated with chronic AC exposure.
Public health initiatives should emphasize proper AC maintenance and monitoring of lung function in individuals exposed
to air conditioning for extended periods, particularly in occupational settings.
Topics

No keywords indexed for this article. Browse by subject →

References
17
[1]
Standardization of Spirometry, 1994 Update. American Thoracic Society
American Review of Respiratory Disease 10.1164/ajrccm.152.3.7663792
[2]
Tanaka T, Sawano H, Nishihara Y, et al. Impact of air conditioning on respiratory health: A comparative study in young adults. J Environ Public Health. 2010;2010: Article ID 491058.
[3]
Al-Hazmi A, Hassan S, Alghamdi S. The effects of long-term air conditioning exposure on respiratory function in office workers. J Occup Environ Med. 2012;54(2):187-92.
[4]
Jacobs P, Fischer S, Scholz S. Mold growth in air conditioning systems: A health risk. Indoor Built Environ. 2013;22(5):699-707.
[5]
Yoon C, Park S, Lee Y. Effects of air conditioning on indoor air quality and respiratory symptoms in asthmatic children. Pediatr Pulmonol. 2014;49(4):385-9.
[6]
Huang H, Li Y, Qian J. Air conditioning and its health impacts: Beneficial or harmful for patients with COPD? Int J Chron Obstruct Pulmon Dis. 2016;11:2001-13.
[7]
American Lung Association. Indoor air pollution and lung health: The role of air conditioning. Lung Assoc Rep. 2014;12:1-5.
[8]
Alhazmi T, Murad A, Halabi K. PFTamong AC users: A cross-sectional study. Saudi J Health Sci. 2016;5(2):98-104.
[9]
Institute of Medicine. Clearing the air: Asthma and indoor air exposures. Washington, D.C.: National Academies Press; 2000.
[10]
National Institute for Occupational Safety and Health (NIOSH). Guidelines for indoor air quality in office buildings. NIOSH Publication No. 2020-102.
[11]
Hulke SM, Patil PM, Thakare AE, Vaidya YP. Lung function test in AC users. J Clin Diagn Res. 2012;6(1):18-20. 10.4103/0975-2870.108629
[12]
Standardisation of spirometry

M. R. Miller, J. Hankinson, V. Brusasco et al.

European Respiratory Journal 10.1183/09031936.05.00034805
[13]
Crapo RO, Morris AH, Gardner RM. Reference spirometric values using techniques and equipment that meet ATS recommendations. Am Rev Respir Dis. 1981;123(6):659-64.
[14]
Ventilation and performance in office work

O. Seppanen, W. J. Fisk, Q. H. Lei

Indoor Air 10.1111/j.1600-0668.2005.00394.x
[15]
Yang C, Lee J, Kim S. Impact of air conditioning system maintenance on respiratory health in patients with asthma and COPD. J Respir Health. 2019;45(3):235-43.
[16]
Zhuang X, Li Y, Ma H. The role of AC filtration capacity in reducing indoor allergens and improving respiratory function. Indoor Air. 2020;30(2):235-43.
[17]
Wang Q, Zhang P, Liu H. The impact of indoor humidity levels in air-conditioned environments on pulmonary outcomes. J Clin Respir Res. 2021;17(1) :112-18.
Metrics
0
Citations
17
References
Details
Published
May 10, 2025
Pages
3065-3072
Cite This Article
Surbhi Ranga, Veenodini Warhade, Janardhan Vishvanath Bhatt, et al. (2025). A Comparative Study of Pulmonary Function Test Results in AC Users Versus Non-Users. International Journal of Innovative Science and Research Technology, 3065-3072. https://doi.org/10.38124/ijisrt/25apr1123