journal article Apr 23, 2024

The Impact of Multileaf Collimator Size on Single Isocenter Dynamic Conformal Arcs-Based Radiosurgery for Brain Metastases

View at Publisher Save 10.7759/cureus.58816
Topics

No keywords indexed for this article. Browse by subject →

References
17
[1]
Gondi V, Meyer J, Shih HA. Advances in radiotherapy for brain metastases. Neurooncol Adv. 2021, 3:v26-34. 10.1093/noajnl/vdab126 10.1093/noajnl/vdab126
[2]
Rogers SJ, Lomax N, Alonso S, Lazeroms T, Riesterer O. Radiosurgery for five to fifteen brain metastases: A single centre experience and a review of the literature. Front Oncol. 2022, 12:866542. 10.3389/fonc.2022.866542 10.3389/fonc.2022.866542
[3]
Yamamoto M, Serizawa T, Shuto T, et al.. Stereotactic radiosurgery for patients with multiple brain metastases (JLGK0901): A multi-institutional prospective observational study. Lancet Oncol. 2014, 15:387-95. 10.1016/S1470-2045(14)70061-0 10.1016/s1470-2045(14)70061-0
[4]
Chea M, Fezzani K, Jacob J, et al.. Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: Impact of target volume geometrical characteristics. Radiat Oncol. 2021, 16:45. 10.1186/s13014-021-01766-w 10.1186/s13014-021-01766-w
[5]
Liu H, Li J, Pappas E, et al.. Dosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcsDosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcs. J Appl Clin Med Phys. 2016, 17:142-56. 10.1120/jacmp.v17i5.6320 10.1120/jacmp.v17i5.6320
[6]
Oshiro Y, Mizumoto M, Kato Y, Tsuchida Y, Tsuboi K, Sakae T, Sakurai H. Single isocenter dynamic conformal arcs-based radiosurgery for brain metastases: Dosimetric comparison with Cyberknife and clinical investigation. Tech Innov Patient Support Radiat Oncol. 2024, 29:100235. 10.1016/j.tipsro.2024.100235 10.1016/j.tipsro.2024.100235
[7]
Abisheva Z, Floyd SR, Salama JK, et al.. The effect of MLC leaf width in single-isocenter multi-target radiosurgery with volumetric modulated arc therapy. J Radiosurg SBRT. 2019, 6:131-8.
[8]
Kairn T, Papworth D, Crowe SB, Anderson J, Christie DR. Dosimetric quality, accuracy, and deliverability of modulated radiotherapy treatments for spinal metastases. Med Dosim. 2016, 41:258-66. 10.1016/j.meddos.2016.06.006 10.1016/j.meddos.2016.06.006
[9]
Tanyi JA, Kato CM, Chen Y, Chen Z, Fuss M. Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery. Br J Radiol. 2011, 84:629-38. 10.1259/bjr/19726857 10.1259/bjr/19726857
[10]
Taylor M, Williams J, Gleason JF Jr. Effects of multileaf collimator design and function when using an optimized dynamic conformal arc approach for stereotactic radiosurgery treatment of multiple brain metastases with a single isocenter: A planning study. Cureus. 2020, 12:e9833. 10.7759/cureus.9833 10.7759/cureus.9833
[11]
Younge KC, Kuchta JR, Mikell JK, Rosen B, Bredfeldt JS, Matuszak MM. The impact of a high-definition multileaf collimator for spine SBRT. J Appl Clin Med Phys. 2017, 18:97-103. 10.1002/acm2.12197 10.1002/acm2.12197
[12]
Levivier M, Wikier D, Goldman S, et al.. Integration of the metabolic data of positron emission tomography in the dosimetry planning of radiosurgery with the gamma knife: early experience with brain tumors. Technical note. J Neurosurg. 2000, 93:233-8. 10.3171/jns.2000.93.supplement 10.3171/jns.2000.93.supplement
[13]
Shaw E, Kline R, Gillin M, Souhami L, Hirschfeld A, Dinapoli R, Martin L.. Radiation therapy oncology group: Radiosurgery quality assurance guidelines. Int J Radiat Oncol Biol Phys. 1993, 27:1231-9. 10.1016/0360-3016(93)90548-a 10.1016/0360-3016(93)90548-a
[14]
Feuvret L, Noël G, Mazeron JJ, Bey P. Conformity index: A review. Int J Radiat Oncol Biol Phys. 2006, 64:333-42. 10.1016/j.ijrobp.2005.09.028 10.1016/j.ijrobp.2005.09.028
[15]
Valiente M, Ahluwalia MS, Boire A, et al.. The evolving landscape of brain metastasis. Trends Cancer. 2018, 4:176-96. 10.1016/j.trecan.2018.01.003 10.1016/j.trecan.2018.01.003
[16]
Paddick I, Lippitz B. A simple dose gradient measurement tool to complement the conformity index. J Neurosurg. 2006, 105 Suppl:194-201. 10.3171/sup.2006.105.7.194 10.3171/sup.2006.105.7.194
[17]
Aiyama H, Yamamoto M, Kawabe T, et al.. Clinical significance of conformity index and gradient index in patients undergoing stereotactic radiosurgery for a single metastatic tumor. J Neurosurg. 2018, 129:103-10. 10.3171/2018.6.GKS181314 10.3171/2018.6.gks181314
Metrics
0
Citations
17
References
Details
Published
Apr 23, 2024
Cite This Article
Yoshiko Oshiro, Yuichi Kato, Masashi Mizumoto, et al. (2024). The Impact of Multileaf Collimator Size on Single Isocenter Dynamic Conformal Arcs-Based Radiosurgery for Brain Metastases. Cureus. https://doi.org/10.7759/cureus.58816
Related

You May Also Like

Artificial Hallucinations in ChatGPT: Implications in Scientific Writing

Hussam Alkaissi, Samy I McFarlane · 2023

803 citations

Role of Physical Activity on Mental Health and Well-Being: A Review

Aditya Mahindru, Pradeep Patil · 2023

311 citations

Epidemiology of Glaucoma: The Past, Present, and Predictions for the Future

Karen Allison, Deepkumar Patel · 2020

256 citations

Obesity: A Chronic Low-Grade Inflammation and Its Markers

Deepesh Khanna, Siya Khanna · 2022

195 citations