Abstract
We present a reduced-order model to calculate response matrices rapidly for filter stack spectrometers (FSSs). The reduced-order model allows response matrices to be built modularly from a set of pre-computed photon and electron transport and scattering calculations through various filter and detector materials. While these modular response matrices are not appropriate for high-fidelity analysis of experimental data, they encode sufficient physics to be used as a forward model in design optimization studies of FSSs, particularly for machine learning approaches that require sampling and testing a large number of FSS designs.
Topics

No keywords indexed for this article. Browse by subject →

References
22
[1]
"A bremsstrahlung spectrometer using k-edge and differential filters with image plate dosimeters" Rev. Sci. Instrum. (2008) 10.1063/1.2964231
[2]
"Novel scintillator-based x-ray spectrometer for use on high repetition laser plasma interaction experiments" Rev. Sci. Instrum. (2018) 10.1063/1.5019213
[3]
"A broadband gamma-ray spectrometry using novel unfolding algorithms for characterization of laser wakefield-generated betatron radiation" Rev. Sci. Instrum. (2015) 10.1063/1.4939014
[4]
"Calorimeter with Bayesian unfolding of spectra of high-flux broadband x rays" Rev. Sci. Instrum. (2022) 10.1063/5.0078443
[5]
"A robust method of x-ray source spectrum estimation from transmission measurements: Demonstrated on computer simulated, scatter-free transmission data" J. Appl. Phys. (2005) 10.1063/1.1928312
[6]
"A multidimensional unfolding method based on Bayes’ theorem" Nucl. Instrum. Methods Phys. Res., Sect. A (1995) 10.1016/0168-9002(95)00274-x
[7]
"Spectrum unfolding, sensitivity analysis and propagation of uncertainties with the maximum entropy deconvolution code MAXED" Nucl. Instrum. Methods Phys. Res., Sect. A (2002) 10.1016/s0168-9002(01)01439-5
[8]
"X-ray spectra estimation using attenuation measurements from 25 kVp to 18 MV" Med. Phys. (1999) 10.1118/1.598622
[9]
"A practical method for estimating high-energy x-ray spectra using the iterative perturbation principle proposed by Waggener" Radiat. Phys. Chem. (2003) 10.1016/s0969-806x(03)00012-4
[10]
Robust unfolding of MeV x-ray spectra from filter stack spectrometer data

C.-S. Wong, J. Strehlow, D. P. Broughton et al.

Review of Scientific Instruments 2024 10.1063/5.0190679
[11]
"MCNP user’s manual code version 6.2" (2017)
[12]
Geant4—a simulation toolkit

S. Agostinelli, J. Allison, K. Amako et al.

Nuclear Instruments and Methods in Physics Researc... 2003 10.1016/s0168-9002(03)01368-8
[13]
(2005)
[14]
"The FLUKA code: Developments and challenges for high energy and medical applications" Nucl. Data Sheets (2014) 10.1016/j.nds.2014.07.049
[15]
(2010)
[16]
"Optimizing MeV photon dose generation in laser-solid interactions via stable beam propagation" (2024)
[17]
"Application of imaging plates to x-ray imaging and spectroscopy in laser plasma experiments (invited)" Rev. Sci. Instrum. (2006) 10.1063/1.2351924
[18]
"High-energy x-ray backlighter spectrum measurements using calibrated image plates" Rev. Sci. Instrum. (2011) 10.1063/1.3531979
[19]
"Validation of modelled imaging plates sensitivity to 1-100 kev x-rays and spatial resolution characterisation for diagnostics for the ‘petawatt aquitaine laser" Rev. Sci. Instrum. (2016) 10.1063/1.4944863
[20]
"Image-plate sensitivity to x rays at 2 to 60 keV" Rev. Sci. Instrum. (2019) 10.1063/1.5053592
[21]
"Calibration of imaging plate for high energy electron spectrometer" Rev. Sci. Instrum. (2005) 10.1063/1.1824371
[22]
"Absolute calibration of image plates for electrons at energy between 100 keV and 4 MeV" Rev. Sci. Instrum. (2008) 10.1063/1.2885045
Cited By
2
Nuclear Instruments and Methods in...
Metrics
2
Citations
22
References
Details
Published
Aug 01, 2024
Vol/Issue
95(8)
License
View
Funding
Laboratory Directed Research and Development Award: 20220018DR
U.S. Department of Energy Award: 89233218CNA000001
Cite This Article
C.-S. Wong, S. V. Luedtke, D. P. Broughton, et al. (2024). Reduced-order model to approximate response matrices for filter stack spectrometers. Review of Scientific Instruments, 95(8). https://doi.org/10.1063/5.0218384
Related

You May Also Like

Modified Spin-Echo Method for Measuring Nuclear Relaxation Times

S. Meiboom, D. Gill · 1958

5,337 citations

Optical trapping

Keir C. Neuman, Steven M. Block · 2004

2,112 citations

Nanoelectromechanical systems

K. L. Ekinci, M. L. Roukes · 2005

1,262 citations